American Wide Flange Beams
American Wide Flange Beams ASTM A6 in metric units
Properties of American Wide Flange Beams according ASTM A6 in metric units are indicated below.
For full table with Static Parameters - Moment of Inertia and Elastic Section Modulus - rotate the screen!
Designation | Dimensions | Static Parameters | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Moment of Inertia | Elastic Section Modulus | |||||||||
Imperal (in x in x lb/ft) | Metric (mm x mm x kg/m) | Depth - h - (mm) | Width - w - (mm) | Web Thickness - s - (mm) | Sectional Area (cm2) | Weight (kg/m) | Ix (cm4) | Iy (cm4) | Sx (cm3) | Sy (cm3) |
W 4 x 4 x 13 | W 100 x 100 x 19.3 | 106 | 103 | 7.1 | 24.7 | 19.3 | 475.9 | 160.6 | 89.9 | 31.2 |
W 5 x 5 x 16 | W 130 x 130 x 23.8 | 127 | 127 | 6.1 | 30.4 | 23.8 | 885.5 | 311 | 139.5 | 49 |
W 5 x 5 x 19 | W 130 x 130 x 28.1 | 131 | 128 | 6.9 | 35.9 | 28.1 | 1099 | 381.4 | 167.7 | 59.6 |
W 6 x 4 x 9 | W 150 x 100 x 13.5 | 150 | 100 | 4.3 | 17.3 | 13.5 | 685.5 | 91.8 | 91.4 | 18.4 |
W 6 x 4 x 12 | W 150 x 100 x 18.0 | 153 | 102 | 5.8 | 22.9 | 18 | 915.9 | 125.9 | 122.1 | 25.4 |
W 6 x 4 x 16 | W 150 x 100 x 24.0 | 160 | 102 | 6.6 | 30.6 | 24 | 1342 | 182.6 | 167.8 | 35.8 |
W 6 x 6 x 15 | W 150 x 150 x 22.5 | 152 | 152 | 5.8 | 28.6 | 22.5 | 1206 | 386.6 | 158.6 | 50.9 |
W 6 x 6 x 20 | W 150 x 150 x 29.8 | 157 | 153 | 6.6 | 37.9 | 29.8 | 1714 | 555.5 | 218.4 | 72.6 |
W 6 x 6 x 25 | W 150 x 150 x 37.1 | 162 | 154 | 8.1 | 47.4 | 37.1 | 2220 | 706.8 | 274.1 | 91.8 |
W 8 x 4 x 10 | W 200 x 100 x 15.0 | 200 | 100 | 4.3 | 19.1 | 15 | 1280 | 86.9 | 128 | 17.4 |
W 8 x 4 x 13 | W 200 x 100 x 19.3 | 203 | 102 | 5.8 | 24.8 | 19.3 | 1662 | 115.4 | 163.7 | 22.6 |
W 8 x 4 x 15 | W 200 x 100 x 22.5 | 206 | 102 | 6.2 | 28.6 | 22.5 | 2004 | 142 | 194.5 | 27.8 |
W 8 x 5.25 x 18 | W 200 x 135 x 26.6 | 207 | 133 | 5.8 | 33.9 | 26.6 | 2587 | 329.8 | 250 | 49.6 |
W 8 x 5.25 x 21 | W 200 x 135 x 31.3 | 210 | 134 | 6.4 | 39.7 | 31.3 | 3139 | 409.6 | 290 | 61.1 |
W 8 x 6.5 x 24 | W 200 x 165 x 35.9 | 201 | 165 | 6.2 | 45.7 | 35.9 | 3438 | 764.3 | 342.1 | 92.6 |
W 8 x 6.5 x 28 | W 200 x 165 x 41.7 | 205 | 166 | 7.2 | 53.2 | 41.7 | 4088 | 900.5 | 399 | 108.5 |
W 8 x 8 x 31 | W 200 x 200 x 46.1 | 203 | 203 | 7.2 | 58.9 | 46.1 | 4545 | 1535 | 448 | 151.2 |
W 8 x 8 x 35 | W 200 x 200 x 52 | 206 | 204 | 7.9 | 66.5 | 52 | 5268 | 1784 | 512 | 174.9 |
W 8 x 8 x 40 | W 200 x 200 x 59 | 210 | 205 | 9.1 | 75.5 | 59 | 6113 | 2040 | 582 | 199.1 |
W 8 x 8 x 48 | W 200 x 200 x 71 | 216 | 206 | 10.2 | 91 | 71 | 7658 | 2537 | 709 | 246.3 |
W 8 x 8 x 58 | W 200 x 200 x 86 | 222 | 209 | 13 | 110 | 86 | 9467 | 3138 | 853 | 300.3 |
W 8 x 8 x 67 | W 200 x 200 x 100 | 229 | 210 | 14.5 | 127 | 100 | 11325 | 3663 | 989 | 348.9 |
W 10 x 4 x 12 | W 250 x 100 x 17.9 | 251 | 101 | 4.8 | 22.8 | 17.9 | 2254 | 91.3 | 179.5 | 18.1 |
W 10 x 4 x 15 | W 250 x 100 x 22.3 | 254 | 102 | 5.8 | 28.5 | 22.3 | 2901 | 122.6 | 228.4 | 24 |
W 10 x 4 x 17 | W 250 x 100 x 25.3 | 257 | 102 | 6.1 | 32.2 | 25.3 | 3430 | 149.2 | 266.9 | 29.3 |
W 10 x 4 x 19 | W 250 x 100 x 28.4 | 260 | 102 | 6.4 | 36.3 | 28.4 | 3998 | 177.5 | 307.5 | 34.8 |
W 10 x 5.75 x 22 | W 250 x 145 x 32.7 | 258 | 146 | 6.1 | 41.9 | 32.7 | 4895 | 472.6 | 379.4 | 64.7 |
W 10 x 5.75 x 26 | W 250 x 145 x 38.5 | 262 | 147 | 6.6 | 49.1 | 38.5 | 6014 | 593.7 | 459.1 | 80.8 |
W 10 x 5.75 x 30 | W 250 x 145 x 44.8 | 266 | 148 | 7.6 | 57 | 44.8 | 7118 | 703.5 | 535.2 | 95.1 |
W 10 x 8 x 33 | W 250 x 200 x 49.1 | 247 | 202 | 7.4 | 62.6 | 49.1 | 7069 | 1513 | 572.4 | 149.8 |
W 10 x 8 x 39 | W 250 x 200 x 58 | 252 | 203 | 8 | 74.2 | 58 | 8736 | 1884 | 693.4 | 185.6 |
W 10 x 8 x 45 | W 250 x 200 x 67 | 257 | 204 | 8.9 | 85.8 | 67 | 10360 | 2224 | 806.6 | 218 |
W 10 x 10 x 49 | W 250 x 250 x 73 | 253 | 254 | 8.6 | 92.9 | 73 | 11290 | 3880 | 892.1 | 305.5 |
W 10 x 10 x 54 | W 250 x 250 x 80 | 256 | 255 | 9.4 | 102 | 80 | 12570 | 4314 | 982.4 | 338.3 |
W 10 x 10 x 60 | W 250 x 250 x 89 | 260 | 256 | 10.7 | 114 | 89 | 14260 | 4841 | 1097 | 378.2 |
W 10 x 10 x 68 | W 250 x 250 x 101 | 264 | 257 | 11.9 | 129 | 101 | 16380 | 5549 | 1241 | 431.9 |
W 10 x 10 x 77 | W 250 x 250 x 115 | 269 | 259 | 13.5 | 146 | 115 | 18940 | 6405 | 1408 | 494.6 |
W 10 x 10 x 88 | W 250 x 250 x 131 | 275 | 261 | 15.4 | 167 | 131 | 22150 | 7446 | 1611 | 570.6 |
W 10 x 10 x 100 | W 250 x 250 x 149 | 282 | 263 | 17.3 | 190 | 149 | 25940 | 8622 | 1840 | 655.7 |
W 10 x 10 x 112 | W 250 x 250 x 167 | 289 | 265 | 19.2 | 212 | 167 | 30020 | 9879 | 2078 | 745.6 |
W 12 x 4 x 14 | W 310 x 100 x 21 | 303 | 101 | 5.1 | 26.8 | 21 | 3708 | 98.3 | 244.8 | 19.5 |
W 12 x 4 x 16 | W 310 x 100 x 23.8 | 305 | 101 | 5.6 | 30.4 | 23.8 | 4280 | 115.6 | 280.7 | 22.9 |
W 12 x 4 x 19 | W 310 x 100 x 28.3 | 309 | 102 | 6 | 35.9 | 28.3 | 5431 | 158.1 | 351.5 | 31 |
W 12 x 4 x 22 | W 310 x 100 x 32.7 | 313 | 102 | 6.6 | 41.8 | 32.7 | 6507 | 191.9 | 415.8 | 37.6 |
W 12 x 6.5 x 26 | W 310 x 165 x 38.7 | 310 | 165 | 5.8 | 49.4 | 38.7 | 8527 | 726.8 | 550.1 | 88.1 |
W 12 x 6.5 x 30 | W 310 x 165 x 44.5 | 313 | 166 | 6.6 | 56.7 | 44.5 | 9934 | 854.7 | 634.8 | 103 |
W 12 x 6.5 x 35 | W 310 x 165 x 52 | 317 | 167 | 7.6 | 66.5 | 52 | 11851 | 1026 | 747.7 | 122.9 |
W 12 x 8 x 40 | W 310 x 200 x 60 | 303 | 203 | 7.5 | 76.1 | 60 | 12860 | 1829 | 849 | 180.8 |
W 12 x 8 x 45 | W 310 x 200 x 67 | 306 | 204 | 8.5 | 85.2 | 67 | 14510 | 2069 | 984 | 202.8 |
W 12 x 8 x 50 | W 310 x 200 x 74 | 310 | 205 | 9.4 | 94.8 | 74 | 16450 | 2344 | 1061 | 228.7 |
W 12 x 10 x 53 | W 310 x 250 x 79 | 306 | 254 | 8.8 | 101 | 79 | 17670 | 3990 | 1155 | 314.2 |
W 12 x 10 x 58 | W 310 x 250 x 86 | 310 | 254 | 9.1 | 110 | 86 | 19850 | 4455 | 1280 | 350.8 |
W 12 x 12 x 65 | W 310 x 310 x 97 | 308 | 305 | 9.9 | 123 | 97 | 22240 | 7286 | 1444 | 477.8 |
W 12 x 12 x 72 | W 310 x 310 x 107 | 311 | 306 | 10.9 | 136 | 107 | 24790 | 8123 | 1594 | 530.9 |
W 12 x 12 x 79 | W 310 x 310 x 117 | 314 | 307 | 11.9 | 150 | 117 | 27510 | 9024 | 1753 | 587.9 |
W 12 x 12 x 87 | W 310 x 310 x 129 | 318 | 308 | 13.1 | 165 | 129 | 30770 | 10040 | 1935 | 651.9 |
W 12 x 12 x 96 | W 310 x 310 x 143 | 323 | 309 | 14 | 182 | 143 | 34760 | 11270 | 2153 | 729.4 |
W 12 x 12 x 106 | W 310 x 310 x 158 | 327 | 310 | 15.5 | 201 | 158 | 38630 | 12470 | 2363 | 804.8 |
W 12 x 12 x 120 | W 310 x 310 x 179 | 333 | 313 | 18 | 228 | 179 | 44530 | 14380 | 2675 | 918.7 |
W 12 x 12 x 136 | W 310 x 310 x 202 | 341 | 315 | 20.1 | 257 | 202 | 51982 | 16588 | 3049 | 1053 |
W 12 x 12 x 152 | W 310 x 310 x 226 | 348 | 317 | 22.1 | 288 | 226 | 59560 | 18930 | 3423 | 1194 |
W 12 x 12 x 170 | W 310 x 310 x 253 | 356 | 319 | 24.4 | 323 | 253 | 68230 | 21460 | 3833 | 1346 |
W 12 x 12 x 190 | W 310 x 310 x 283 | 365 | 322 | 26.9 | 360 | 283 | 78680 | 24590 | 4311 | 1527 |
W 12 x 12 x 210 | W 310 x 310 x 313 | 374 | 325 | 30 | 399 | 313 | 89560 | 27700 | 4789 | 1705 |
W 12 x 12 x 230 | W 310 x 310 x 342 | 382 | 328 | 32.6 | 437 | 342 | 100510 | 31020 | 5262 | 1892 |
- 1 cm4 = 104 mm4 = 10-8 m4 = 0.024 in4
- 1 cm3 = 103 mm3 = 10-6 m3 = 0.061 in3
- 1 cm2 = 102 mm2 = 10-4 m2 = 0.16 in2
- 1 kg/m = 0.67 lb/ft
Example - Converting Moment of Inertia from cm4 to mm4
The Ix Moment of Inertia of beam W 12 x 12 x 230 is 100510 cm4. It can be converted to mm4 by multiplying with 104 as
(100510 cm4) (104 mm4/cm4) = 1005100000 mm4
= 1005 106 mm4
The standard method for specifying the dimensions of a American Wide Flange Beam is for example W 310 x 250 x 79, which is 310 mm deep, 250 mm wide and with a weight of 79 kg/m.
I-shaped cross-section beams:
- Britain : Universal Beams (UB) and Universal Columns (UC)
- Europe : IPE. HE. HL. HD and other sections
- US : Wide Flange (WF) and H sections