Ethane Liquid - Thermal Properties
Thermal properties of liquid Ethane C2H6 at the vapor liquid phase boundary.
For full table with Density and Speed of Sound - rotate the screen!
| Temperature - T - (K) | Pressure - p - (kPa) | Enthalpy - h - (kJ/kg) | Entropy - s - (kJ/kgK) | Specific Heat Capacity - cv - (kJ/kgK) | Specific Heat - cp - (kJ/kgK) | Speed of Sound - c - (m/s) | Density - ρ - (kg/m3) |
|---|---|---|---|---|---|---|---|
| 90.368 (triple point) |
0.0011 | -889 | -5.06 | 1.61 | 2.33 | 2008 | 652 |
| 120 | 0.352 | -821 | -4.41 | 1.48 | 2.28 | 1794 | 619 |
| 150 | 9.64 | -752 | -3.90 | 1.44 | 2.33 | 1576 | 585 |
| 160 | 21.4 | -729 | -3.75 | 1.44 | 2.36 | 1501 | 574 |
| 170 | 42.8 | -705 | -3.60 | 1.43 | 2.39 | 1426 | 562 |
| 180 | 78.6 | -681 | -3.46 | 1.43 | 2.42 | 1350 | 550 |
| 184 | 98.3 | -671 | -3.41 | 1.44 | 2.44 | 1320 | 545 |
| Standard Temperature and Pressure | |||||||
| 186 | 109.4 | -666 | -3.38 | 1.44 | 2.45 | 1305 | 542 |
| 190 | 134.6 | -656 | -3.33 | 1.44 | 2.46 | 1274 | 537 |
| 200 | 217.2 | -631 | -3.21 | 1.44 | 2.51 | 1196 | 524 |
| 210 | 333.8 | -606 | -3.08 | 1.45 | 2.57 | 1117 | 510 |
| 220 | 492.1 | -580 | -2.96 | 1.47 | 2.65 | 1037 | 496 |
| 230 | 700.2 | -553 | -2.84 | 1.49 | 2.73 | 956 | 481 |
| 240 | 966.8 | -525 | -2.73 | 1.51 | 2.85 | 873 | 465 |
| 250 | 1301 | -496 | -2.61 | 1.53 | 2.99 | 788 | 448 |
| 260 | 1711 | -465 | -2.49 | 1.57 | 3.20 | 701 | 429 |
| 270 | 2210 | -432 | -2.38 | 1.61 | 3.49 | 609 | 408 |
| 280 | 2807 | -397 | -2.25 | 1.65 | 3.99 | 512 | 383 |
| 300 | 4357 | -305 | -1.95 | 1.91 | 10.02 | 275 | 304 |
| 305.322 (critical point) |
4872 | -230.7 | -1.71 | 206 |
Ethane is an organic chemical compound with chemical formula C2H6.
Related Topics
• Material Properties
Properties of gases, fluids and solids. Densities, specific heats, viscosities and more.
Related Documents
Combustion Heat
Heat of combustion (energy content) for som common substances - with examples how to calculate heat of combustion.
Ethane - Density and Specific Weight vs. Temperature and Pressure
Online calculator, figures and tables showing density and specific weight of ethane, C2H6, at varying temperature and pressure - Imperial and SI Units.
Ethane - Thermophysical Properties
Chemical, Physical and Thermal Properties of Ethane - C2H6.
Ethane Gas - Specific Heat vs. Temperature
Specific heat of Ethane Gas - C2H6 - for temperatures ranging 250 - 900 K.
Gases - Explosion and Flammability Concentration Limits
Flame and explosion limits for gases like propane, methane, butane, acetylene and more.
Heating Values of Fuel Gases
Combustion heat values for gases like acetylene, blast furnace gas, ethane, biogas and more - Gross and Net values.
Substances Triple Points
Triple points for common substances.