Ethane Liquid - Thermal Properties
Density, specific heat and more of liquid ethane.
Thermal properties of liquid Ethane C2H6 at the vapor liquid phase boundary.
For full table with Density and Speed of Sound - rotate the screen!
| Temperature - T - (K) | Pressure - p - (kPa) | Enthalpy - h - (kJ/kg) | Entropy - s - (kJ/kgK) | Specific Heat Capacity - cv - (kJ/kgK) | Specific Heat - cp - (kJ/kgK) | Speed of Sound - c - (m/s) | Density - ρ - (kg/m3) |
|---|---|---|---|---|---|---|---|
| 90.368 (triple point) |
0.0011 | -889 | -5.06 | 1.61 | 2.33 | 2008 | 652 |
| 120 | 0.352 | -821 | -4.41 | 1.48 | 2.28 | 1794 | 619 |
| 150 | 9.64 | -752 | -3.90 | 1.44 | 2.33 | 1576 | 585 |
| 160 | 21.4 | -729 | -3.75 | 1.44 | 2.36 | 1501 | 574 |
| 170 | 42.8 | -705 | -3.60 | 1.43 | 2.39 | 1426 | 562 |
| 180 | 78.6 | -681 | -3.46 | 1.43 | 2.42 | 1350 | 550 |
| 184 | 98.3 | -671 | -3.41 | 1.44 | 2.44 | 1320 | 545 |
| Standard Temperature and Pressure | |||||||
| 186 | 109.4 | -666 | -3.38 | 1.44 | 2.45 | 1305 | 542 |
| 190 | 134.6 | -656 | -3.33 | 1.44 | 2.46 | 1274 | 537 |
| 200 | 217.2 | -631 | -3.21 | 1.44 | 2.51 | 1196 | 524 |
| 210 | 333.8 | -606 | -3.08 | 1.45 | 2.57 | 1117 | 510 |
| 220 | 492.1 | -580 | -2.96 | 1.47 | 2.65 | 1037 | 496 |
| 230 | 700.2 | -553 | -2.84 | 1.49 | 2.73 | 956 | 481 |
| 240 | 966.8 | -525 | -2.73 | 1.51 | 2.85 | 873 | 465 |
| 250 | 1301 | -496 | -2.61 | 1.53 | 2.99 | 788 | 448 |
| 260 | 1711 | -465 | -2.49 | 1.57 | 3.20 | 701 | 429 |
| 270 | 2210 | -432 | -2.38 | 1.61 | 3.49 | 609 | 408 |
| 280 | 2807 | -397 | -2.25 | 1.65 | 3.99 | 512 | 383 |
| 300 | 4357 | -305 | -1.95 | 1.91 | 10.02 | 275 | 304 |
| 305.322 (critical point) |
4872 | -230.7 | -1.71 | 206 |
Ethane is an organic chemical compound with chemical formula C2H6.