Carbon Steel Flanges - Pressure and Temperature Ratings - Group 1.1
Maximum temperature and pressure ratings of flanges conforming dimensions ASME B16.5 and materials specification ASTM A-105
Maximum temperature and pressure ratings of flanges conforming dimensions ASME B16.5 Pipe Flanges and Flanged Fittings - and materials specification ASTM A-105 Specification for Carbon Steel Forgings for Piping Applications - temperature in Fahrenheit and pressure in psi.
| Gage Pressure (psi) | |||||||
|---|---|---|---|---|---|---|---|
| Temperature (oF) | Flange Class | ||||||
| 150 | 300 | 400 | 600 | 900 | 1500 | 2500 | |
| < 100 | 285 | 740 | 985 | 1480 | 2220 | 3705 | 6170 |
| 200 | 260 | 680 | 905 | 1360 | 2035 | 3395 | 5655 |
| 300 | 230 | 655 | 870 | 1310 | 1965 | 3270 | 5450 |
| 400 | 200 | 635 | 845 | 1265 | 1900 | 3170 | 5280 |
| 500 | 170 | 605 | 805 | 1205 | 1810 | 3015 | 5025 |
| 600 | 140 | 570 | 755 | 1135 | 1705 | 2840 | 4730 |
| 650 | 125 | 550 | 730 | 1100 | 1650 | 2745 | 4575 |
| 700 | 110 | 530 | 710 | 1060 | 1590 | 2655 | 4425 |
| 750 | 95 | 505 | 675 | 1015 | 1520 | 2535 | 4230 |
| 800 | 80 | 410 | 550 | 825 | 1235 | 2055 | 3430 |
| 850 | 65 | 320 | 425 | 640 | 955 | 1595 | 2655 |
| 900 | 50 | 230 | 305 | 460 | 690 | 1150 | 1915 |
| 950 | 35 | 135 | 185 | 275 | 410 | 685 | 1145 |
| 1000 | 20 | 85 | 115 | 170 | 255 | 430 | 715 |
| Hydrostatic Test Pressure (psig) | 450 | 1125 | 1500 | 2225 | 3350 | 5575 | 9275 |
The values are for materials Group 1.1
- 1 psi (lb/in2) = 144 psf (lbf/ft2) = 6,894.8 Pa (N/m2) = 6.895x10-3 N/mm2 = 6.895x10-2 bar
- tC = 5/9 (tF - 32)
Insert flanges to your Sketchup model with the Engineering ToolBox Sketchup Extension
Related Topics
Related Documents
Tag Search
- en: carbon steel flanges classes
- es: clases de bridas de acero al carbono
- de: Kohlenstoffstahlflanschen Klassen