Square Hollow Structural Sections (HSS) – Sizes, Strength & Specifications
Add Structural Sections to your Sketchup model with the Enginering ToolBox extension
- 1 in = 25.4 mm
For full table - rotate the screen!
| Nominal Size 3) | Weight | Wall Thickness | b/t 1) | h/t 1) | Cross Sectional Area 2) | I 1) | S 1) | r 1) | Z 1) | Torsional Stiffness Constant J | Torsional Shear Constant C | Surface Area |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| (in x in x in) | (lbf/ft) | (in) | - | - | (in2) | (in4) | (in3) | (in) | (in3) | (in4) | (in3) | (ft2/ft) |
| 32 x 32 x 5/8 | 259.83 | 0.625 | 48.2 | 48.2 | 76.4 | 12300 | 771 | 12.7 | 890 | 19700 | 1230 | 10.34 |
| 32 x 32 x 1/2 | 210.72 | 0.500 | 61.0 | 61.0 | 61.9 | 10100 | 634 | 12.8 | 727 | 15900 | 991 | 10.45 |
| 32 x 32 x 3/8 | 159.37 | 0.375 | 82.3 | 82.3 | 46.8 | 7750 | 485 | 12.9 | 553 | 12000 | 750 | 10.51 |
| 30 x 30 x 5/8 | 242.82 | 0.625 | 45.0 | 45.0 | 71.4 | 10100 | 673 | 11.9 | 778 | 16200 | 1070 | 9.68 |
| 30 x 30 x 1/2 | 197.11 | 0.500 | 57.0 | 57.0 | 57.9 | 8320 | 555 | 12.0 | 637 | 13000 | 869 | 9.79 |
| 30 x 30 x 3/8 | 149.16 | 0.375 | 77.0 | 77.0 | 43.8 | 6370 | 424 | 12.1 | 485 | 9870 | 658 | 9.84 |
| 28 x 28 x 5/8 | 225.80 | 0.625 | 41.8 | 41.8 | 66.4 | 8140 | 582 | 11.1 | 674 | 13100 | 933 | 9.01 |
| 28 x 28 x 1/2 | 183.50 | 0.500 | 53.0 | 53.0 | 53.9 | 6730 | 480 | 11.2 | 552 | 10600 | 755 | 9.12 |
| 28 x 28 x 3/8 | 138.95 | 0.375 | 71.7 | 71.7 | 40.8 | 5150 | 368 | 11.2 | 421 | 8010 | 572 | 9.17 |
| 26 x 26 x 5/8 | 208.79 | 0.625 | 38.6 | 38.6 | 61.4 | 6460 | 497 | 10.3 | 577 | 10500 | 801 | 8.34 |
| 26 x 26 x 1/2 | 169.89 | 0.500 | 49.0 | 49.0 | 49.9 | 5350 | 411 | 10.4 | 474 | 8430 | 649 | 8.45 |
| 26 x 26 x 3/8 | 128.74 | 0.375 | 66.3 | 66.3 | 37.8 | 4110 | 316 | 10.4 | 362 | 6400 | 492 | 8.51 |
| 24 x 24 x 5/8 | 191.78 | 0.625 | 35.4 | 35.4 | 56.4 | 5030 | 419 | 9.44 | 487 | 8180 | 679 | 7.68 |
| 24 x 24 x 1/2 | 156.28 | 0.500 | 45.0 | 45.0 | 45.9 | 4170 | 348 | 9.53 | 401 | 6610 | 551 | 7.79 |
| 24 x 24 x 3/8 | 118.53 | 0.375 | 61.0 | 61.0 | 34.8 | 3210 | 268 | 9.60 | 307 | 5020 | 418 | 7.84 |
| 22 x 22 x 5/8 | 174.76 | 0.625 | 32.2 | 32.2 | 51.4 | 3820 | 347 | 8.62 | 406 | 6260 | 567 | 7.01 |
| 22 x 22 x 1/2 | 142.67 | 0.500 | 41.0 | 41.0 | 41.9 | 3190 | 290 | 8.72 | 335 | 5070 | 461 | 7.12 |
| 22 x 22 x 3/8 | 108.32 | 0.375 | 55.7 | 55.7 | 31.8 | 2460 | 223 | 8.78 | 256 | 3850 | 350 | 7.17 |
| 20 x 20 x 5/8 | 157.75 | 0.625 | 29.0 | 29.0 | 46.4 | 2830 | 283 | 7.81 | 331 | 4670 | 465 | 6.34 |
| 20 x 20 x 1/2 | 129.06 | 0.500 | 37.0 | 37.0 | 37.9 | 2370 | 237 | 7.90 | 275 | 3790 | 379 | 6.45 |
| 20 x 20 x 3/8 | 98.12 | 0.375 | 50.3 | 50.3 | 28.8 | 1830 | 183 | 7.97 | 211 | 2880 | 288 | 6.51 |
| 18 x 18 x 5/8 | 140.73 | 0.625 | 25.8 | 25.8 | 41.4 | 2020 | 224 | 6.99 | 264 | 3370 | 373 | 5.68 |
| 18 x 18 x 1/2 | 115.45 | 0.500 | 33.0 | 33.0 | 33.9 | 1700 | 189 | 7.08 | 220 | 2740 | 305 | 5.79 |
| 18 x 18 x 3/8 | 87.91 | 0.375 | 45.0 | 45.0 | 25.8 | 1320 | 147 | 7.15 | 169 | 2090 | 232 | 5.84 |
| 16 x 16 x 5/8 | 127.37 | 0.581 | 24.5 | 24.5 | 35.0 | 1370 | 171 | 6.25 | 200 | 2170 | 276 | 5.17 |
| 16 x 16 x 1/2 | 103.30 | 0.465 | 31.4 | 31.4 | 28.3 | 1130 | 141 | 6.31 | 164 | 1770 | 224 | 5.20 |
| 16 x 16 x 3/8 | 78.52 | 0.349 | 42.8 | 42.8 | 21.5 | 873 | 109 | 6.37 | 126 | 1350 | 171 | 5.23 |
| 16 x 16 x 5/16 | 65.87 | 0.291 | 52.0 | 52.0 | 18.1 | 739 | 92.3 | 6.39 | 106 | 1140 | 144 | 5.25 |
| 14 x 14 x 5/8 | 110.36 | 0.581 | 21.1 | 21.1 | 30.3 | 896 | 128 | 5.44 | 151 | 1430 | 208 | 4.50 |
| 14 x 14 x 1/2 | 89.68 | 0.465 | 27.1 | 27.1 | 24.6 | 743 | 106 | 5.49 | 124 | 1170 | 170 | 4.53 |
| 14 x 14 x 3/8 | 68.31 | 0.349 | 37.1 | 37.1 | 18.7 | 577 | 82.5 | 5.55 | 95.4 | 900 | 130 | 4.57 |
| 14 x 14 x 5/16 | 57.36 | 0.291 | 45.1 | 45.1 | 15.7 | 490 | 69.9 | 5.58 | 80.5 | 759 | 109 | 4.58 |
| 12 x 12 x 5/8 | 93.34 | 0.581 | 17.7 | 17.7 | 25.7 | 548 | 91.3 | 4.62 | 109 | 885 | 151 | 3.83 |
| 12 x 12 x 1/2 | 76.07 | 0.465 | 22.8 | 22.8 | 20.9 | 457 | 76.2 | 4.68 | 89.6 | 728 | 123 | 3.87 |
| 12 x 12 x 3/8 | 58.10 | 0.349 | 31.4 | 31.4 | 16.0 | 357 | 59.5 | 4.73 | 69.2 | 561 | 94.6 | 3.90 |
| 12 x 12 x 5/16 | 48.86 | 0.291 | 38.2 | 38.2 | 13.4 | 304 | 50.7 | 4.76 | 58.6 | 474 | 79.7 | 3.92 |
| 12 x 12 x 1/4 | 39.43 | 0.233 | 48.5 | 48.5 | 10.8 | 248 | 41.4 | 4.79 | 47.6 | 384 | 64.5 | 3.93 |
| 10×10 x 5/8 | 76.33 | 0.581 | 14.2 | 14.2 | 21.0 | 304 | 60.8 | 3.80 | 73.2 | 498 | 102 | 3.17 |
| 10×10 x 1/2 | 62.46 | 0.465 | 18.5 | 18.5 | 17.2 | 256 | 51.2 | 3.86 | 60.7 | 412 | 84.2 | 3.20 |
| 10×10 x 3/8 | 47.90 | 0.349 | 25.7 | 25.7 | 13.2 | 202 | 40.4 | 3.92 | 47.2 | 320 | 64.8 | 3.23 |
| 10×10 x 5/16 | 40.35 | 0.291 | 31.4 | 31.4 | 11.1 | 172 | 34.5 | 3.94 | 40.1 | 271 | 54.8 | 3.25 |
| 10×10 x 1/4 | 32.63 | 0.233 | 39.9 | 39.9 | 8.96 | 141 | 28.3 | 3.97 | 32.7 | 220 | 44.4 | 3.27 |
| 10×10 x 3/16 | 24.73 | 0.174 | 54.5 | 54.5 | 6.76 | 108 | 21.6 | 4.00 | 24.8 | 167 | 33.6 | 3.28 |
| 9 x 9 x 1/2 | 55.66 | 0.465 | 16.4 | 16.4 | 15.3 | 182 | 40.6 | 3.45 | 48.4 | 296 | 67.4 | 2.87 |
| 9 x 9 x 3/8 | 42.79 | 0.349 | 22.8 | 22.8 | 11.8 | 145 | 32.2 | 3.51 | 37.8 | 231 | 52.1 | 2.90 |
| 9 x 9 x 5/16 | 36.10 | 0.291 | 27.9 | 27.9 | 9.92 | 124 | 27.6 | 3.54 | 32.1 | 196 | 44.0 | 2.92 |
| 9 x 9 x 1/4 | 29.23 | 0.233 | 35.6 | 35.6 | 8.03 | 102 | 22.7 | 3.56 | 26.2 | 159 | 35.8 | 2.93 |
| 9 x 9 x 3/16 | 22.18 | 0.174 | 48.7 | 48.7 | 6.06 | 78.2 | 17.4 | 3.59 | 20.0 | 121 | 27.1 | 2.95 |
| 8 x 8 x 5/8 | 59.32 | 0.581 | 10.8 | 10.8 | 16.4 | 146 | 36.5 | 2.99 | 44.7 | 244 | 63.2 | 2.50 |
| 8 x 8 x 1/2 | 48.85 | 0.465 | 14.2 | 14.2 | 13.5 | 125 | 31.2 | 3.04 | 37.5 | 204 | 52.4 | 2.53 |
| 8 x 8 x 3/8 | 37.69 | 0.349 | 19.9 | 19.9 | 10.4 | 99.6 | 24.9 | 3.10 | 29.4 | 160 | 40.7 | 2.57 |
| 8 x 8 x 5/16 | 31.84 | 0.291 | 24.5 | 24.5 | 8.76 | 85.6 | 21.4 | 3.13 | 25.1 | 136 | 34.5 | 2.58 |
| 8 x 8 x 1/4 | 25.82 | 0.233 | 31.3 | 31.3 | 7.10 | 70.7 | 17.7 | 3.15 | 20.5 | 111 | 28.1 | 2.60 |
| 8 x 8 x 3/16 | 19.63 | 0.174 | 43.0 | 43.0 | 5.37 | 54.4 | 13.6 | 3.18 | 15.7 | 84.5 | 21.3 | 2.62 |
| 7 x 7 x 5/8 | 50.81 | 0.581 | 9.0 | 9.0 | 14.0 | 93.3 | 26.7 | 2.58 | 33.1 | 158 | 47.1 | 2.17 |
| 7 x 7 x 1/2 | 42.05 | 0.465 | 12.1 | 12.1 | 11.6 | 80.5 | 23.0 | 2.63 | 27.9 | 133 | 39.3 | 2.20 |
| 7 x 7 x 3/8 | 32.58 | 0.349 | 17.1 | 17.1 | 8.97 | 64.9 | 18.6 | 2.69 | 22.1 | 105 | 30.7 | 2.23 |
| 7 x 7 x 5/16 | 27.59 | 0.291 | 21.1 | 21.1 | 7.59 | 56.1 | 16.0 | 2.72 | 18.9 | 89.7 | 26.1 | 2.25 |
| 7 x 7 x 1/4 | 22.42 | 0.233 | 27.0 | 27.0 | 6.17 | 46.5 | 13.3 | 2.75 | 15.5 | 73.5 | 21.3 | 2.27 |
| 7 x 7 x 3/16 | 17.08 | 0.174 | 37.2 | 37.2 | 4.67 | 36.0 | 10.3 | 2.77 | 11.9 | 56.1 | 16.2 | 2.28 |
| 6 x 6 x 5/8 | 42.30 | 0.581 | 7.3 | 7.3 | 11.7 | 55.1 | 18.4 | 2.17 | 23.2 | 94.9 | 33.4 | 1.83 |
| 6 x 6 x 1/2 | 35.24 | 0.465 | 9.9 | 9.9 | 9.74 | 48.2 | 16.1 | 2.23 | 19.8 | 81.1 | 28.1 | 1.87 |
| 6 x 6 x 3/8 | 27.48 | 0.349 | 14.2 | 14.2 | 7.58 | 39.4 | 13.1 | 2.28 | 15.8 | 64.6 | 22.1 | 1.90 |
| 6 x 6 x 5/16 | 23.34 | 0.291 | 17.6 | 17.6 | 6.43 | 34.3 | 11.4 | 2.31 | 13.6 | 55.4 | 18.9 | 1.92 |
| 6 x 6 x 1/4 | 19.02 | 0.233 | 22.8 | 22.8 | 5.24 | 28.6 | 9.54 | 2.34 | 11.2 | 45.6 | 15.4 | 1.93 |
| 6 x 6 x 3/16 | 14.53 | 0.174 | 31.5 | 31.5 | 3.98 | 22.3 | 7.42 | 2.37 | 8.63 | 35.0 | 11.8 | 1.95 |
| 6 x 6 x 1/8 | 9.86 | 0.116 | 48.7 | 48.7 | 2.70 | 15.5 | 5.15 | 2.39 | 5.92 | 23.9 | 8.03 | 1.97 |
| 5-1/2 x 5-1/2 x 3/8 | 24.93 | 0.349 | 12.8 | 12.8 | 6.88 | 29.7 | 10.8 | 2.08 | 13.1 | 49.0 | 18.4 | 1.73 |
| 5-1/2 x 5-1/2 x 5/16 | 21.21 | 0.291 | 15.9 | 15.9 | 5.85 | 25.9 | 9.43 | 2.11 | 11.3 | 42.2 | 15.7 | 1.75 |
| 5-1/2 x 5-1/2 x 1/4 | 17.32 | 0.233 | 20.6 | 20.6 | 4.77 | 21.7 | 7.90 | 2.13 | 9.32 | 34.8 | 12.9 | 1.77 |
| 5-1/2 x 5-1/2 x 3/16 | 13.25 | 0.174 | 28.6 | 28.6 | 3.63 | 17.0 | 6.17 | 2.16 | 7.19 | 26.7 | 9.85 | 1.78 |
| 5-1/2 x 5-1/2 x 1/8 | 9.01 | 0.116 | 44.4 | 44.4 | 2.46 | 11.8 | 4.30 | 2.19 | 4.95 | 18.3 | 6.72 | 1.80 |
| 5 x 5 x 1/2 | 28.43 | 0.465 | 7.8 | 7.8 | 7.88 | 26.0 | 10.4 | 1.82 | 13.1 | 44.6 | 18.7 | 1.53 |
| 5 x 5 x 3/8 | 22.37 | 0.349 | 11.3 | 11.3 | 6.18 | 21.7 | 8.67 | 1.87 | 10.6 | 36.1 | 14.9 | 1.57 |
| 5 x 5 x 5/16 | 19.08 | 0.291 | 14.2 | 14.2 | 5.26 | 19.0 | 7.61 | 1.90 | 9.16 | 31.2 | 12.8 | 1.58 |
| 5 x 5 x 1/4 | 15.62 | 0.233 | 18.5 | 18.5 | 4.30 | 16.0 | 6.41 | 1.93 | 7.61 | 25.8 | 10.5 | 1.60 |
| 5 x 5 x 3/16 | 11.97 | 0.174 | 25.7 | 25.7 | 3.28 | 12.6 | 5.03 | 1.96 | 5.89 | 19.9 | 8.08 | 1.62 |
| 5 x 5 x 1/8 | 8.16 | 0.116 | 40.1 | 40.1 | 2.23 | 8.80 | 3.52 | 1.99 | 4.07 | 13.7 | 5.53 | 1.63 |
| 4-1/2 x 4-1/2 x 1/2 | 25.03 | 0.465 | 6.7 | 6.7 | 6.95 | 18.0 | 8.02 | 1.61 | 10.2 | 31.3 | 14.8 | 1.37 |
| 4-1/2 x 4-1/2 x 3/8 | 19.82 | 0.349 | 9.9 | 9.9 | 5.48 | 15.3 | 6.78 | 1.67 | 8.36 | 25.7 | 11.9 | 1.40 |
| 4-1/2 x 4-1/2 x 5/16 | 16.96 | 0.291 | 12.5 | 12.5 | 4.68 | 13.5 | 5.99 | 1.70 | 7.27 | 22.3 | 10.2 | 1.42 |
| 4-1/2 x 4-1/2 x 1/4 | 13.91 | 0.233 | 16.3 | 16.3 | 3.84 | 11.4 | 5.08 | 1.73 | 6.06 | 18.5 | 8.44 | 1.43 |
| 4-1/2 x 4-1/2 x 3/16 | 10.70 | 0.174 | 22.9 | 22.9 | 2.93 | 9.02 | 4.01 | 1.75 | 4.71 | 14.4 | 6.49 | 1.45 |
| 4-1/2 x 4-1/2 x 1/8 | 7.31 | 0.116 | 35.8 | 35.8 | 2.00 | 6.35 | 2.82 | 1.78 | 3.27 | 9.92 | 4.45 | 1.47 |
| 4 x 4 x 1/2 | 21.63 | 0.465 | 5.6 | 5.6 | 6.02 | 11.9 | 5.95 | 1.41 | 7.70 | 21.0 | 11.2 | 1.20 |
| 4 x 4 x 3/8 | 17.27 | 0.349 | 8.5 | 8.5 | 4.78 | 10.3 | 5.13 | 1.46 | 6.39 | 17.5 | 9.14 | 1.23 |
| 4 x 4 x 5/16 | 14.83 | 0.291 | 10.7 | 10.7 | 4.10 | 9.14 | 4.57 | 1.49 | 5.59 | 15.3 | 7.91 | 1.25 |
| 4 x 4 x 1/4 | 12.21 | 0.233 | 14.2 | 14.2 | 3.37 | 7.80 | 3.90 | 1.52 | 4.69 | 12.8 | 6.56 | 1.27 |
| 4 x 4 x 3/16 | 9.42 | 0.174 | 20.0 | 20.0 | 2.58 | 6.21 | 3.10 | 1.55 | 3.67 | 9.96 | 5.07 | 1.28 |
| 4 x 4 x 1/8 | 6.46 | 0.116 | 31.5 | 31.5 | 1.77 | 4.40 | 2.20 | 1.58 | 2.56 | 6.91 | 3.49 | 1.30 |
| 3-1/2 x 3-1/2 x 3/8 | 14.72 | 0.349 | 7.0 | 7.0 | 4.09 | 6.48 | 3.70 | 1.26 | 4.69 | 11.2 | 6.77 | 1.07 |
| 3-1/2 x 3-1/2 x 5/16 | 12.70 | 0.291 | 9.0 | 9.0 | 3.52 | 5.84 | 3.34 | 1.29 | 4.14 | 9.89 | 5.90 | 1.08 |
| 3-1/2 x 3-1/2 x 1/4 | 10.51 | 0.233 | 12.0 | 12.0 | 2.91 | 5.04 | 2.88 | 1.32 | 3.50 | 8.35 | 4.92 | 1.10 |
| 3-1/2 x 3-1/2 x 3/16 | 8.15 | 0.174 | 17.1 | 17.1 | 2.24 | 4.05 | 2.31 | 1.35 | 2.76 | 6.56 | 3.83 | 1.12 |
| 3-1/2 x 3-1/2 x 1/8 | 5.61 | 0.116 | 27.2 | 27.2 | 1.54 | 2.90 | 1.66 | 1.37 | 1.93 | 4.58 | 2.65 | 1.13 |
| 3 x 3 x 3/8 | 12.17 | 0.349 | 5.6 | 5.6 | 3.39 | 3.77 | 2.51 | 1.05 | 3.25 | 6.64 | 4.74 | 0.90 |
| 3 x 3 x 5/16 | 10.58 | 0.291 | 7.3 | 7.3 | 2.94 | 3.45 | 2.30 | 1.08 | 2.90 | 5.94 | 4.18 | 0.92 |
| 3 x 3 x 1/4 | 8.81 | 0.233 | 9.9 | 9.9 | 2.44 | 3.02 | 2.01 | 1.11 | 2.48 | 5.08 | 3.52 | 0.93 |
| 3 x 3 x 3/16 | 6.87 | 0.174 | 14.2 | 14.2 | 1.89 | 2.46 | 1.64 | 1.14 | 1.97 | 4.03 | 2.76 | 0.95 |
| 3 x 3 x 1/8 | 4.75 | 0.116 | 22.9 | 22.9 | 1.30 | 1.78 | 1.19 | 1.17 | 1.40 | 2.84 | 1.92 | 0.97 |
| 2-1/2 x 2-1/2 x 5/16 | 8.45 | 0.291 | 5.6 | 5.6 | 2.35 | 1.82 | 1.45 | 0.879 | 1.88 | 3.20 | 2.74 | 0.75 |
| 2-1/2 x 2-1/2 x 1/4 | 7.11 | 0.233 | 7.7 | 7.7 | 1.97 | 1.63 | 1.30 | 0.908 | 1.63 | 2.79 | 2.35 | 0.77 |
| 2-1/2 x 2-1/2 x 3/16 | 5.59 | 0.174 | 11.4 | 11.4 | 1.54 | 1.35 | 1.08 | 0.937 | 1.32 | 2.25 | 1.86 | 0.78 |
| 2-1/2 x 2-1/2 x 1/8 | 3.90 | 0.116 | 18.6 | 18.6 | 1.07 | 0.998 | 0.798 | 0.965 | 0.947 | 1.61 | 1.31 | 0.80 |
| 2-1/4 x 2-1/4 x 1/4 | 6.26 | 0.233 | 6.7 | 6.7 | 1.74 | 1.13 | 1.00 | 0.805 | 1.28 | 1.96 | 1.85 | 0.68 |
| 2-1/4 x 2-1/4 x 3/16 | 4.96 | 0.174 | 9.9 | 9.9 | 1.37 | 0.952 | 0.847 | 0.835 | 1.04 | 1.60 | 1.48 | 0.70 |
| 2-1/4 x 2-1/4 x 1/8 | 3.48 | 0.116 | 16.4 | 16.4 | 0.96 | 0.712 | 0.633 | 0.863 | 0.755 | 1.15 | 1.05 | 0.72 |
| 2 x 2 x 1/4 | 5.41 | 0.233 | 5.6 | 5.6 | 1.51 | 0.745 | 0.745 | 0.703 | 0.964 | 1.31 | 1.41 | 0.60 |
| 2 x 2 x 3/16 | 4.32 | 0.174 | 8.5 | 8.5 | 1.19 | 0.640 | 0.640 | 0.732 | 0.797 | 1.09 | 1.14 | 0.62 |
| 2 x 2 x 1/8 | 3.05 | 0.116 | 14.2 | 14.2 | 0.84 | 0.486 | 0.486 | 0.761 | 0.584 | 0.796 | 0.817 | 0.63 |
| 1-3/4 x 1-3/4 x 3/16 | 3.68 | 0.174 | 7.1 | 7.1 | 1.02 | 0.405 | 0.462 | 0.630 | 0.585 | 0.699 | 0.844 | 0.53 |
| 1-5/8 x 1-5/8 x 3/16 | 3.36 | 0.174 | 6.3 | 6.3 | 0.93 | 0.312 | 0.384 | 0.579 | 0.491 | 0.544 | 0.712 | 0.49 |
| 1-5/8 x 1-5/8 x 1/8 | 2.42 | 0.116 | 11.0 | 11.0 | 0.67 | 0.246 | 0.302 | 0.608 | 0.370 | 0.410 | 0.522 | 0.51 |
| 1-1/2 x 1-1/2 x 3/16 | 3.04 | 0.174 | 5.6 | 5.6 | 0.84 | 0.235 | 0.314 | 0.528 | 0.406 | 0.414 | 0.592 | 0.45 |
| 1-1/2 x 1-1/2 x 1/8 | 2.20 | 0.116 | 9.9 | 9.9 | 0.61 | 0.188 | 0.251 | 0.556 | 0.309 | 0.316 | 0.438 | 0.47 |
| 1-1/4 x 1-1/4 x 3/16 | 2.40 | 0.174 | 4.2 | 4.2 | 0.67 | 0.121 | 0.194 | 0.425 | 0.259 | 0.218 | 0.383 | 0.37 |
| 1-1/4 x 1-1/4 x 1/8 | 1.78 | 0.116 | 7.8 | 7.8 | 0.49 | 0.101 | 0.162 | 0.454 | 0.204 | 0.174 | 0.292 | 0.38 |
1)
- b - nominal width minus 3 times the design wall thickness t
- t - design wall thickness
- h - nominal depth minus 3 times the design wall thickness t
- I - moment of inertia of cross-section
- S - elastic section modulus
- r - radius of gyration
- Z - plastic section modulus
2)Note that the cross sectional areas are calculated for sections with rounded corners (outside corner radii equal to 2 times the design wall thickness).
3) Note that nominal thickness may not be the same as actual thickness. Actual thickness may vary with manufacturing methods.
Related Topics
• Beams and Columns
Deflection and stress in beams and columns, moment of inertia, section modulus and technical information.
Related Documents
American Standard Beams - S Beam
American Standard Beams ASTM A6 - Imperial units.
American Standard Steel Channels: Weight, Dimensions & Properties
Dimensions and static parameters of American Standard Steel C Channels
American Wide Flange Steel Beams (W-Beams) - Dimensions and Properties in Imperial Units
Dimensions, weight, section properties, and essential data of American wide flange steel beams (W-beams) according to the ASTM A6 standard.
American Wide Flange Steel Beams: Dimensions and Properties (ASTM A6 in Metric)
American Wide Flange Beams ASTM A6 in metric units.
Beam Loads - Support Force Calculator
Calculate beam load and supporting forces.
Beams - Fixed at One End and Supported at the Other - Continuous and Point Loads
Supporting loads, moments and deflections.
Beams Fixed at Both Ends with Continuous and Point Loads: Load & Deflection Formulas
Stress, deflections and supporting loads.
Beams Supported at Both Ends with Continuous and Point Loads: Stress, Deflection, Formulas and Calculators
Supporting loads, stress and deflections.
British Universal Columns and Beams
Properties of British Universal Steel Columns and Beams.
Cantilever Beam Calculations: Formulas, Loads & Deflections
Maximum reaction forces, deflections and moments - single and uniform loads.
Factors of Safety - FOS
Factors of Safety - FOS - are important in engineering designs.
HE-A Steel Beams
Properties of HE-A profiled steel beams.
Modulus of Rigidity
Shear Modulus (Modulus of Rigidity) is the elasticity coefficient for shearing or torsion force.
Radius of Gyration in Structural Engineering
Radius of gyration describes the distribution of cross sectional area in columns around their centroidal axis.
Square Hollow Structural Sections (HSS) – Sizes, Strength & Specifications
Weight, cross sectional area, moments of inertia - Imperial units
Square Hollow Structural Sections (HSS) – Sizes, Strength & Specifications
Weight, cross sectional area, moments of inertia - Imperial units
Steel Angles - Equal Legs
Dimensions and static parameters of steel angles with equal legs - metric units.
Steel Angles - Unequal Legs
Dimensions and static parameters of steel angles with unequal legs - imperial units.
Steel Angles - Unequal Legs
Dimensions and static parameters of steel angles with unequal legs - metric units.
Steel Pipe Columns - Allowable Loads
Allowable concentric loads for steel pipe columns.
Young’s Modulus of Elasticity – Values for Common Materials
Young’s Modulus (Elastic Modulus) of various materials, including metals, plastics, and composites. How stiffness and elasticity influence material performance in engineering applications.