Hyperbolic Functions
Hyperbolic Functions
Hyperbolic functions are combinations of the exponentials ex and e-x.
sinh x = (ex - e-x) / 2 (1)
cosh x = (ex + e-x) / 2 (2)
tanh x = sinh x / cosh x = (ex - e-x) / (ex + e-x) (3)
Values for Hyperbolic Functions
| x | ex | e-x | sinh x | cosh x | tanh x |
|---|---|---|---|---|---|
| 0.00 | 1 | 1 | 0 | 1 | 0 |
| 0.05 | 1.0513 | 0.9512 | 0.050021 | 1.00125 | 0.0499584 |
| 0.10 | 1.1052 | 0.9048 | 0.10017 | 1.00500 | 0.099668 |
| 0.15 | 1.1618 | 0.8607 | 0.15056 | 1.01127 | 0.14889 |
| 0.20 | 1.2214 | 0.8187 | 0.20134 | 1.02007 | 0.19738 |
| 0.25 | 1.2840 | 0.7788 | 0.25261 | 1.03141 | 0.24492 |
| 0.30 | 1.3499 | 0.7408 | 0.30452 | 1.04534 | 0.29131 |
| 0.35 | 1.4191 | 0.7047 | 0.35719 | 1.06188 | 0.33638 |
| 0.40 | 1.4918 | 0.6703 | 0.41075 | 1.08107 | 0.37995 |
| 0.45 | 1.5683 | 0.6376 | 0.46534 | 1.10297 | 0.42190 |
| 0.50 | 1.6487 | 0.6065 | 0.52110 | 1.12763 | 0.46212 |
| 0.55 | 1.7333 | 0.5769 | 0.57815 | 1.15510 | 0.50052 |
| 0.60 | 1.8221 | 0.5488 | 0.63665 | 1.18547 | 0.53705 |
| 0.65 | 1.9155 | 0.5220 | 0.69675 | 1.21879 | 0.57167 |
| 0.70 | 2.0138 | 0.4966 | 0.75858 | 1.25517 | 0.60437 |
| 0.75 | 2.1170 | 0.4724 | 0.82232 | 1.29468 | 0.63515 |
| 0.80 | 2.2255 | 0.4493 | 0.88811 | 1.33743 | 0.66404 |
| 0.85 | 2.3396 | 0.4274 | 0.95612 | 1.38353 | 0.69107 |
| 0.90 | 2.4596 | 0.4066 | 1.0265 | 1.43309 | 0.71630 |
| 0.95 | 2.5857 | 0.3867 | 1.0995 | 1.48623 | 0.73978 |
| 1.0 | 2.7183 | 0.3679 | 1.1752 | 1.54308 | 0.76159 |
| 1.1 | 3.0042 | 0.3329 | 1.3356 | 1.66852 | 0.80050 |
| 1.2 | 3.3201 | 0.3012 | 1.5095 | 1.81066 | 0.83365 |
| 1.3 | 3.6693 | 0.2725 | 1.6984 | 1.97091 | 0.86172 |
| 1.4 | 4.0552 | 0.2466 | 1.9043 | 2.15090 | 0.88535 |
| 1.5 | 4.4817 | 0.2231 | 2.1293 | 2.35241 | 0.90515 |
| 1.6 | 4.9530 | 0.2019 | 2.3756 | 2.57746 | 0.92167 |
| 1.7 | 5.4739 | 0.1827 | 2.6456 | 2.82832 | 0.93541 |
| 1.8 | 6.0496 | 0.1653 | 2.9422 | 3.10747 | 0.94681 |
| 1.9 | 6.6859 | 0.1496 | 3.2682 | 3.41773 | 0.95624 |
| 2.0 | 7.3891 | 0.1353 | 3.6269 | 3.76220 | 0.96403 |
| 2.5 | 12.182 | 0.08208 | 6.0502 | 6.13229 | 0.98661 |
| 3.0 | 20.086 | 0.04979 | 10.018 | 10.068 | 0.99505 |
| 3.5 | 33.115 | 0.03020 | 16.543 | 16.573 | 0.99818 |
| 4.0 | 54.598 | 0.01832 | 27.290 | 27.308 | 0.99933 |
| 4.5 | 90.017 | 0.01111 | 45.003 | 45.014 | 0.99975 |
| 5.0 | 148.41 | 0.006738 | 74.203 | 74.210 | 0.99991 |
| 5.5 | 244.69 | 0.004087 | 122.34 | 122.35 | 0.99997 |
| 6.0 | 403.43 | 0.002479 | 201.71 | 201.72 | 0.99999 |
| 6.5 | 665.14 | 0.001503 | 332.57 | 332.57 | 1.00000 |
| 7.0 | 1096.6 | 0.0009119 | 548.32 | 548.32 | 1.00000 |
| 7.5 | 1808.0 | 0.0005531 | 904.02 | 904.02 | 1.00000 |
| 8.0 | 2981.0 | 0.0003355 | 1490.5 | 1490.5 | 1.00000 |
| 8.5 | 4914.8 | 0.0002035 | 2457.4 | 2457.4 | 1.00000 |
| 9.0 | 8103.1 | 0.00012341 | 4051.5 | 4051.5 | 1.00000 |
| 9.5 | 13360 | 0.00007485 | 6679.9 | 6679.9 | 1.00000 |
| 10 | 22026 | 0.000045400 | 11013 | 11013 | 0.999999996 |
Inverse Hyperbolic Functions
sinh-1(x) = loge(x + (x2 + 1)1/2) (4)
cosh-1(x) = loge(x ± (x2 + 1)1/2) x ≥ 1 (5)
tanh-1(x) = 1/2 loge((1 + x) / (1 - x)) x2 ‹ 1 (6)
Related Topics
• Mathematics
Mathematical rules and laws - numbers, areas, volumes, exponents, trigonometric functions and more.
Related Documents
Algebraic Expressions
Principal algebraic expressions formulas.
Complex Numbers
Complex numbers are used in alternating current theory and mechanical vector analysis.
Elementary Surfaces
Ellipsoid, sphere, hyperboloid, cone and more.
Fractions
Law of fractions
Law of Cosines
One side of a triangle when the opposite angle and two sides are known.
Oblique Triangle
Calculate oblique triangles.
Polynomial Equation of nth Degree
The polynomial nth degree equation.
Pythagorean Theorem
Verifying square corners.
Spherical and Cylindrical Coordinates
3D cylindrical and spherical coordinate systems
Standard Differentials and Integrals
Equations for differentials and integrals.
Taylor Series
Function as an infinite sum of terms.
Trigonometric Functions
Sine, cosine and tangent - the natural trigonometric functions.