Chemical resistance of CPVC - Chlorinated Poly (Vinyl Chloride) - to common chemicals and products.

Sponsored Links

Recommended and not recommended chemicals in combination with CPVC - Chlorinated Poly(Vinyl Chloride) - pipes:

Chemicals Recommended

  • Acetaldehyde, up to 10 %
  • Acetaldehyde, >10%
  • Acetaldehyde, pure
  • Acetic Acid, up to 10%
  • Acetic Acid, >10%
  • Acetic Acid, pure
  • Acetic Anhydride
  • Acetone, up to 5%
  • Acetone, >5%
  • Acetone, pure
  • Acetonitrile, up to 10%
  • Acetonitrile, >10%
  • Acetonitrile, pure
  • Acetyl Chloride
  • Acrylic Acid, aqueous
  • Acrylic Acid, pure
  • Acrylonitrile, aqueous
  • Acrylonitrile, pure
  • Adipic Acid
  • Allyl Alcohol, aqueous
  • Allyl Alcohol, pure
  • Alum
  • Aluminum Acetate
  • Aluminum Chloride
  • Aluminum Fluoride
  • Aluminum Hydroxide
  • Aluminum Nitrate
  • Aluminum Sulfate
  • Ammonia
  • Ammonium Acetate
  • Ammonium Benzoate
  • Ammonium Bifuoride
  • Ammonium Carbonate
  • Ammonium Chloride
  • Ammonium Citrate
  • Ammonium Dichromate
  • Ammonium Fluoride
  • Ammonium Hydroxide
  • Ammonium Metaphosphate
  • Ammonium Nitrate
  • Ammonium Persulfate
  • Ammonium Phosphate
  • Ammonium Sulfamate
  • Ammonium Sulfate
  • Ammonium Sulfde
  • Ammonium Thiocyanate
  • Ammonium Tartrate
  • Amyl Alcohol, up to 1%
  • Antimony Trichloride, aqueous
  • Aqua Regia
  • Arsenic Acid
  • Aryl Sulfonic Acid
  • Barium Carbonate
  • Barium Chloride
  • Barium Hydroxide
  • Barium Nitrate
  • Barium Sulfate
  • Barium Sulfde
  • Beer
  • Beet Sugar Liquors
  • Benzene Sulfonic Acid
  • Benzoic Acid, aqueous
  • Benzyl Alcohol
  • Bismuth Carbonate
  • Black Liquor
  • Bleach
  • Blood
  • Borax
  • Boric Acid
  • Brine Acid
  • Bromic Acid
  • Bromine, liquid
  • Bromine, aqueous
  • Butanol, up to 1%
  • Butanol, >1%
  • Butanol, pure
  • Butyl Carbitol
  • Butyl Cellosolve
  • Butyric Acid, up to 1%
  • Butyric Acid, >1%
  • Butyric Acid, pure
  • Cadmium Acetate
  • Cadmium Chloride
  • Cadmium Cyanide
  • Cadmium Sulfate
  • Calcium Acetate
  • Calcium Bisulfde
  • Calcium Bisulfte
  • Calcium Carbonate
  • Calcium Chlorate
  • Calcium Chloride
  • Calcium Hydroxide
  • Calcium Hypochlorite
  • Calcium Nitrate
  • Calcium Oxide
  • Calcium Sulfate
  • Cane Sugar Liquors
  • Caprolactam, aqueous
  • Caprolactone, aqueous
  • Carbitol
  • Carbolic Acid, up to 5%
  • Carbolic Acid, >5%
  • Carbolic Acid, pure
  • Carbonic Acid
  • Caustic Potash
  • Caustic Soda
  • Cellosolve
  • Cellosolve Acetate
  • Chloramine, aqueous
  • Chloric Acid
  • Chlorine, aqueous
  • Chlorine dioxide, aqueous
  • Chloroacetic Acid, up to 25%
  • Chloroacetic Acid, >25%
  • Chloroacetic Acid, pure
  • Chromic Acid, 40%
  • Chromium Nitrate
  • Citric Acid
  • Citrus Oils
  • Coffee
  • Copper Acetate
  • Copper Carbonate
  • Copper Chloride
  • Copper Cyanide
  • Copper Fluoride
  • Copper Nitrate
  • Copper Sulfate
  • Corn Syrup
  • Crotonaldehyde
  • Cupric Fluoride
  • Cupric Sulfate
  • Cuprous Chloride
  • Cyclohexane
  • Cyclohexanol
  • Cyclohexanone
  • Decahydronaphthalene
  • Detergents
  • Dextrin
  • Dextrose
  • Diacetone Alcohol
  • Dibutyl Ether
  • Dichlorobenzene
  • Diethylamine
  • Diethyl Cellosolve
  • Diethyl Ether
  • Diglycolic Acid
  • Dill Oil
  • Dimethylamine
  • Dimethylformamide
  • Dimethylhydrazine
  • Disodium Phosphate
  • Dioxane, up to 30%
  • Dioxane, >30%
  • Dioxane, pure
  • Distilled Water
  • EDTA, Tetrasodium-
  • Ethanol, up to 10%
  • Ethanol, >10%
  • Ethanol, pure
  • Ethyl Acetate
  • Ethyl Acetoacetate
  • Ethyl Acrylate
  • Ethyl Ether
  • Ethyl Formate
  • Ethyl Mercaptan
  • Ethyl Oxalate
  • Ethylene Glycol, up to 50%
  • Ethylene Glycol, >50%
  • Ethylene Oxide
  • Ethylenediamine
  • 2-ethylhexanol
  • Ferric Chloride
  • Ferric Hydroxide
  • Ferric Nitrate
  • Ferric Sulfate
  • Ferrous Chloride
  • Ferrous Hydroxide
  • Ferrous Nitrate
  • Ferrous Sulfate
  • Fluoboric Acid
  • Fluosilicic Acid
  • Formaldehyde
  • Formic Acid, up to 25%
  • Formic Acid, >25%
  • Formic Acid, pure
  • Fructose
  • Furfural
  • Gallic Acid, aqueous
  • Gasoline
  • Gelatine
  • Glucose
  • Glycerine
  • Glycolic Acid
  • Glyoxal, aqueous
  • Green Liquor
  • Heptane
  • Hexane
  • Hexanol
  • Hydrazine
  • Hydrobromic Acid
  • Hydrochloric Acid
  • Hydrocyanic Acid
  • Hydrofuoric Acid
  • Hydrogen Peroxide, 10%
  • Hydrogen Peroxide, 30%
  • Hydrogen Peroxide, 50%
  • Hydrogen Sulfde, aqueous
  • Hydroquinone, aqueous
  • Hydroxylamine Sulfate
  • Hypochlorous Acid
  • Iodine
  • Isobutyl Alcohol
  • Isophorone
  • Isopropanol, up to 5%
  • Isopropanol, >5%
  • Isopropanol, pure
  • Isopropyl Acetate
  • Isopropyl Ether
  • Kerosene
  • Ketchup
  • Kraft Liquors
  • Lactic Acid
  • Lead Acetate
  • Lead Chloride
  • Lead Nitrate
  • Lead Sulfate
  • Lemon Oil
  • Ligroin
  • Limonene
  • Lithium Bromide
  • Lithium Chloride
  • Lithium Hydroxide
  • Lithium Sulfate
  • Magnesium Carbonate
  • Magnesium Chloride
  • Magnesium Citrate
  • Magnesium Fluoride
  • Magnesium Hydroxide
  • Magnesium Nitrate
  • Magnesium Oxide
  • Magnesium Sulfate
  • Maleic Acid
  • Malic Acid
  • Manganese Sulfate
  • Mercuric Chloride
  • Mercuric Cyanide
  • Mercuric Sulfate
  • Mercurous Nitrate
  • Mercury
  • Methanesulfonic Acid
  • Methanol, up to 10%
  • Methanol, >10%
  • Methanol, pure
  • Methyl Acetate, up to 5%
  • Methyl Acetate, >5%
  • Methyl Acetate, pure
  • Methyl Cellosolve
  • Methyl Ethyl Ketone
  • Methyl Formate
  • Methyl Isobutyl Ketone
  • Methyl Isopropyl Ketone
  • Methyl Methacrylate
  • Methylamine
  • Mineral Oil
  • Molasses
  • Monoethanolamine
  • Morpholine
  • Muriatic Acid
  • Nickel Acetate
  • Nickel Chloride
  • Nickel Nitrate
  • Nickel Sulfate
  • Nitric Acid
  • Nitrous Acid
  • Octane
  • Octanol
  • Oleum
  • Oxalic Acid
  • Ozonized Water
  • Paraffn
  • Peracetic Acid
  • Perchloric Acid, 10%
  • Phenol, up to 5%
  • Phenol, >5%
  • Phenol, pure
  • Phosphoric Acid
  • Phosphorus Pentoxide
  • Phosphorus Trichloride
  • Photographic Solutions
  • Pine Oil
  • Plating Solutions
  • Polyethylene Glycol
  • Polyvinyl Alcohol
  • Potash
  • Potassium Acetate
  • Potassium Bicarbonate
  • Potassium Bichromate
  • Potassium Bisulfate
  • Potassium Borate
  • Potassium Bromate
  • Potassium Bromide
  • Potassium Carbonate
  • Potassium Chlorate
  • Potassium Chloride
  • Potassium Chromate
  • Potassium Cyanate
  • Potassium Cyanide
  • Potassium Dichromate
  • Potassium Ferricyanide
  • Potassium Ferrocyanide
  • Potassium Fluoride
  • Potassium Hydroxide
  • Potassium Hypochlorite
  • Potassium Iodide
  • Potassium Nitrate
  • Potassium Perborate
  • Potassium Perchlorate
  • Potassium Permanganate
  • Potassium Persulfate
  • Potassium Phosphate
  • Potassium Sulfate
  • Potassium Sulfde
  • Potassium Sulfte
  • Potassium Tripolyphosphate
  • Propanol, up to 1%
  • Propanol, >1%
  • Propanol, pure
  • Propargyl Alcohol
  • Propionic Acid, up to 5%
  • Propionic Acid, >5%
  • Propionic Acid, pure
  • Propyl Acetate
  • Propylene Glycol, up to 25%
  • Propylene Glycol, >25%
  • Propylene Oxide
  • Pyridine
  • Pyrogallol
  • Pyrrole
  • Salicylaldehyde
  • Sea Water
  • Silicic Acid
  • Silicone Oil
  • Silver Chloride
  • Silver Cyanide
  • Silver Nitrate
  • Silver Sulfate
  • Soaps
  • Sodium Acetate
  • Sodium Aluminate
  • Sodium Arsenate
  • Sodium Benzoate
  • Sodium Bicarbonate
  • Sodium Bichromate
  • Sodium Bisulfate
  • Sodium Bisulfte
  • Sodium Borate
  • Sodium Bromide
  • Sodium Carbonate
  • Sodium Chlorate
  • Sodium Chloride
  • Sodium Chlorite
  • Sodium Chromate
  • Sodium Cyanide
  • Sodium Dichromate
  • Sodium Ferricyanide
  • Sodium Ferrocyanide
  • Sodium Fluoride
  • Sodium Formate
  • Sodium Hydroxide
  • Sodium Hypobromite
  • Sodium Hypochlorite
  • Sodium Iodide
  • Sodium Metaphosphate
  • Sodium Nitrate
  • Sodium Nitrite
  • Sodium Palmitate
  • Sodium Perborate
  • Sodium Perchlorate
  • Sodium Peroxide
  • Sodium Phosphate
  • Sodium Silicate
  • Sodium Sulfate
  • Sodium Sulfde
  • Sodium Sulfte
  • Sodium Thiosulfate
  • Sodium Tripolyphosphate
  • Stannic Chloride
  • Stannous Chloride
  • Stannous Sulfate
  • Starch
  • Stearic Acid
  • Strontium Chloride
  • Succinic Acid
  • Sugar
  • Sulfamic Acid
  • Sulfuric Acid
  • Sulfurous Acid
  • Tannic Acid
  • Tartaric Acid
  • Tetrahydrofuran
  • Tetrahydronaphthalene
  • Tetrasodium pyrophosphate
  • Thionyl Chloride
  • Tomato Juice
  • Tributyl Citrate
  • Tributyl Phosphate
  • Trichloroacetic Acid
  • Triethanolamine
  • Triethylamine
  • Trimethyl Propane
  • Trisodium Phosphate
  • Urea
  • Urine
  • Vinegar
  • Vinyl Acetate
  • Water
  • Whiskey
  • White Liquor
  • Wine
  • Zinc Acetate
  • Zinc Carbonate
  • Zinc Chloride
  • Zinc Nitrate
  • Zinc Sulfate

Chemicals Not Recommended

  • Allyl Chloride
  • Asphalt
  • Benzyl Chloride
  • Bromobenzene
  • Bromotoluene
  • Carbon Tetrachloride
  • Chlorobenzene
  • Chloroform
  • Creosote
  • Cresol
  • Dibutoxyethyl Phthalate
  • Dibutyl Phthalate
  • Dibutyl Sebacate
  • Dichloroethylene
  • Dimethyl Phthalate
  • Dioctyl Phthalate
  • Ethyl Chloride
  • Ethyl Chloroacetate
  • Ethylene Bromide
  • Ethylene Chloride
  • Ethylene Chlorohydrin
  • Halocarbon Oils
  • Isopropyl Chloride
  • Methyl Chloride
  • Methyl Chloroform
  • Methylene Bromide
  • Methylene Chloride
  • Methylene Chlorobromide
  • Methylene Iodide
  • Motor Oil
  • Phosphate Esters
  • Propyl Bromide
  • Propylene Dichloride
  • Trichloroethylene

Chemicals used with Caution

Be suspicious with certain stress levels.

  • Acetophenone
  • Amines
  • Amyl Acetate
  • Amyl Alcohol, >1%
  • Amyl Alcohol, pure
  • Amyl Chloride
  • Aniline
  • Aniline Hydrochloride
  • Anthraquinone
  • Benzaldehyde
  • Benzene
  • Butyl Acetate
  • Butyl Phenol
  • Carbon Disulfde
  • Castor Oil
  • Coconut Oil
  • Corn Oil
  • Cottonseed Oil
  • Cumene
  • Diesel Fuel
  • Ethyl Benzene
  • Fatty Acids
  • Fish Oil
  • Lard Oil
  • Lauryl Chloride
  • Linoleic Acid
  • Linseed Oil
  • Naphtha
  • Naphthalene
  • Nitrobenzene
  • Nitroethane
  • Nitroglycerine
  • Nitromethane
  • Oil, Crude
  • Olive Oil
  • Palm Oil
  • Peanut Oil
  • Phenylhydrazine
  • Phthalic Acid
  • Picric Acid
  • Soybean Oil
  • Styrene
  • Tall Oil
  • Toluene
  • Tung Oil
  • Turpentine
  • Vegetable Oils
  • Xylene
Sponsored Links

Related Topics

Related Documents

Sponsored Links

Share

Search Engineering ToolBox

  • the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.

Topics

Unit Converters

Temperature

oC
oF


Load Calculator!

Length

m
km
in
ft
yards
miles
naut miles


Load Calculator!

Area

m2
km2
in2
ft2
miles2
acres


Load Calculator!

Volume

m3
liters
in3
ft3
us gal


Load Calculator!

Weight

kgf
N
lbf


Load Calculator!

Velocity

m/s
km/h
ft/min
ft/s
mph
knots


Load Calculator!

Pressure

Pa (N/m2)
bar
mm H2O
kg/cm2
psi
inches H2O


Load Calculator!

Flow

m3/s
m3/h
US gpm
cfm


Load Calculator!

9 1

This website use cookies. By continuing to browse you are agreeing to our use of cookies! Learn more