Kinematic Viscosity - Unit Converter
Convert between the kinematic viscosity units Centistokes, Saybolt and Redwood seconds:
| Centistokes | Redwood | Saybolt SUS | Engler |
|---|---|---|---|
| 2 | 30.8 | 32.6 | 1.12 |
| 2.3 | 31.5 | 33.7 | 1.15 |
| 2.6 | 32.3 | 34.8 | 1.18 |
| 2.9 | 33.0 | 35.7 | 1.21 |
| 3.2 | 33.8 | 36.7 | 1.24 |
| 3.5 | 34.5 | 37.7 | 1.26 |
| 3.8 | 35.3 | 38.6 | 1.29 |
| 4.5 | 37.0 | 40.8 | 1.35 |
| 6 | 40.9 | 45.6 | 1.48 |
| 7.5 | 44.9 | 50.4 | 1.61 |
| 9 | 49.0 | 55.5 | 1.75 |
| 11 | 54.9 | 62.4 | 1.93 |
| 14 | 64.5 | 73.5 | 2.22 |
| 17 | 74.8 | 85.2 | 2.54 |
| 20 | 85.7 | 97.6 | 2.87 |
| 23 | 97.0 | 110 | 3.22 |
| 26 | 109 | 123 | 3.58 |
| 29 | 120 | 137 | 3.95 |
| 32 | 132 | 150 | 4.32 |
| 35 | 144 | 163 | 4.70 |
| 38 | 156 | 177 | 5.08 |
| 41 | 168 | 191 | 5.47 |
| 44 | 180 | 204 | 5.85 |
| 47 | 192 | 218 | 6.24 |
| 50 | 204 | 232 | 6.62 |
| 65 | 265 | 301 | 8.55 |
| 80 | 326 | 370 | 10.5 |
| 95 | 387 | 440 | 12.5 |
| 100 | 407 | 463 | 13.2 |
- Values valid for temperature 50 oC (122 oF) - can be used for approximate calculations between 20 oC ( 68 oF) and 100 oC (212 oF) .
Kinematic Viscosity Chart
Related Topics
• Fluid Mechanics
The study of fluids - liquids and gases. Involving velocity, pressure, density and temperature as functions of space and time.
• Viscosities
Viscosities of products and chemical species at varying conditions.
Related Documents
Dynamic, Absolute, and Kinematic Viscosity – Definitions & Conversions
The differences between dynamic, absolute, and kinematic viscosity - a fluids resistance to flow - with definitions, unit conversions, and practical applications for engineers and scientists.
Crude Oil Viscosity vs. Gravity
Viscosity at 20°C/68°F and 50°C/122°F for more than 120 crudes is shown as function of specific gravity@15°C/60°F.
Kinematic Viscosity - Online Converter
Convert between kinematic viscosity units like centistokes, poise, lentor and more.
Liquids - Kinematic Viscosities
Kinematic viscosities of some common liquids like motor oil, diesel fuel, peanut oil and many more.
Oil Fuels - Viscosities vs. Temperatures
Viscosities of fuel oils vs. temperature.
Propane - Dynamic and Kinematic Viscosity vs. Temperature and Pressure
Online calculators, figures and tables showing dynamic and kinematic viscosity of liquid and gaseous propane at varying temperarure and pressure, SI and Imperial units.
Steel Pipes - Viscous Liquid Flow and Friction Loss
Friction loss in schedule 40 steel pipe with viscous liquids - viscosities ranging from water to oil.
Water - Dynamic and Kinematic Viscosity at Various Temperatures and Pressures
Free online calculator - figures and tables with viscosity of water at temperatures ranging 0 to 360°C (32 to 675°F) - Imperial and SI Units.