Compressed Air - Size of Pipe vs. Capacity
Recommended air pipe line sizes with schedule 40 steel pipes and air pressure 100 psi (6.9 bar, 689500 Pa):
Free Air Flow (cfm) | Recommended Pipe Size (inches) | ||||||
|---|---|---|---|---|---|---|---|
| Length of Pipe (feet) | |||||||
| 25 | 50 | 75 | 100 | 150 | 200 | 250 | |
| 5 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
| 10 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
| 15 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 |
| 20 | 1/2 | 1/2 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 |
| 25 | 1/2 | 3/4 | 3/4 | 3/4 | 3/4 | 1 | 1 |
| 30 | 1/2 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 |
| 35 | 3/4 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 |
| 40 | 3/4 | 3/4 | 3/4 | 1 | 1 | 1 | 1 |
| 45 | 3/4 | 3/4 | 1 | 1 | 1 | 1 | 1 1/4 |
| 50 | 3/4 | 1 | 1 | 1 | 1 | 1 1/4 | 1 1/4 |
| 55 | 3/4 | 1 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 |
| 60 | 3/4 | 1 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 |
| 65 | 3/4 | 1 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 |
| 70 | 3/4 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 |
| 75 | 1 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 |
| 80 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 |
| 85 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 |
| 90 | 1 | 1 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/2 |
| 95 | 1 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/2 |
| 100 | 1 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/4 | 1 1/2 | 1 1/2 |
Related Topics
• Gases and Compressed Air
Properties of air, LNG, LPG and other common gases. Pipeline capacities and sizing of relief valves.
Related Documents
Compressed Air - Friction Loss in Hoses
Friction loss in air hoses vs. operating pressure.
Compressed Air - Pipe Line Pressure Loss - Online Calculator with Metric and Imperial Units
Calculate pressure drop in compressed air pipe lines - metric and imperial units.
Compressed Air - Pressure Drop Diagrams, Metric Units
Pressure loss in compressed air pipe lines.
Compressed Air Pipe Line Capacity
Capacities of compressed air pipelines - pressure ranging 5 - 250 psi (0.5 - 17 bar).
Compressed Air Pipe Lines - Pressure Loss vs. Capacity and Operating Pressure
Pressure drop in compressed air pipe lines.
Compressed Air Pipes - Fittings and Pressure Loss
Fittings in compressed air pipe lines and equivalent length pressure drop.
Compressed Air Piping - Pressure Loss Diagrams, Imperial Units
Pressure drop in compressed air pipelines with applied pressure 50, 100 and 150 psi.
Pneumatic Piping - Pressure Loss vs. Air Flow
Pressure loss in pneumatic tubes - sizes ranging 5 - 36 mm.