Dimensions of PVC pipes according EN 1401.

Dimensions of PVC pipes according EN 1401 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinylchloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system:

EN 1401 - PVC Piping Systems for Non-Pressure Underground Drainage and Sewerage
Nominal Size
DN/OD
(mm)
Nominal Outside Diameter
(mm)
Mean Outside Diameter (mm)
minmax
110 110 110.0 110.3
125 125 125.0 125.3
160 160 160.0 160.4
200 200 200.0 200.5
250 250 250.0 250.5
315 315 315.0 315.6
400 400 400.0 400.7
500 500 500.0 500.9
630 630 630.0 631.1
800 800 800.0 801.3
1000 1000 1000.0 1001.6