Steam consumption rates for typical steam heated consumers
IndustryApplicationOperating PressureConsumption productionConsumption maximum
psigbarlb/hkg/hlb/hkg/h
Bakeries Dough room trough, 8 ft long 10 1 5 2
Proof Boxes, 500 cu ft capacity 10 1 10 5
Ovens 0 0
White bread, 120 sq ft surface 10 1 30 14
Rye bread, 10 sq ft surface 10 1 60 27
Breweries Bottle washing, normal size 100 bottles/min 5 0.3 300 136
Candy and Chocolate Candy cooking, 30 gal cooker, 1 hour 70 5 45 20
Chocolate melting, jacketed, 24 inch diameter 70 5 30 14
Candy kettle per sq ft of jacket 70 5 0 60 27
Creameries and Dairies Milk quarts per 100 cases per hr 5 0.3 60 27
Creamery cans 3 per min 50 3 300 136
Pasteurizer per 100 gal heated 20 min 50 3 250 113
Hospitals tills per 100 gal distilled water 50 3 100 45
Sterilizers bed pan 50 3 5 2
Sterilizers instruments per 100 cu inch 50 3 5 2
Sterilizers water per 10 gal 50 3 5 2
Disinfecting ovens 100 cu ft, per 10 cu ft 50 3 25 11
Laundry Vacuum stills per 10 gal 100 7 15 7
Spotting board 100 7 30 14
Jacket, dress finisher 100 7 50 23
Steam Irons 100 7 5 2
Flat iron worker, 48'' * 120'' 100 7 300 136
Plastic Molding 12 to 15 sq ft platen surface 125 9 30 14
Paper Production Corrugators per 1000 sq ft 175 12 30 14
Wood pulp paper per 10 lb paper 50 3 400 181
Restaurants Dishwasher 20 1 70 32
Standard steam tables per ft length 20 1 40 18
Bain Marie per ft length 30 '' wide 20 1 15 7
Oyster steamers 20 1 15 7
Clam and lobster steamer 20 1 30 14
Steam jacket kettle 10 gal 20 1 15 7 100 45
Steam jacket kettle 60 gal 20 1 60 27 200 91
Plate and dish warmers per 100 sq ft 20 1 60 27
Warming ovens per 20 cu ft 20 1 30 14
Vegetable steamer 20 1 30 14
Potato Steamer 20 1 30 14
Tire Shops Truck molds 100 7 90 41
Passenger molds 100 7 30 14