Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

CSI MasterFormat Specifications

Construction Specifications Institute's 2004 Master-Format Edition.

The Construction Specifications Institute's (CSI) MasterFormat is the most widely used standard for organizing specifications for building projects in the U.S. and Canada.

MasterFormat organizes information by work results (materials and methods) with the primary purposes of organizing specifications and detailed cost information. MasterFormat is normally used from design development on in the design construction process.

Master-Format 2004 Edition:

PROCUREMENT AND CONTRACTING REQUIREMENTS GROUP

  • Division 00 — Procurement and Contracting Requirements

SPECIFICATIONS GROUP

General Requirements Subgroup

  • Division 01 — General Requirements

Facility Construction Subgroup

  • Division 02 — Existing Conditions
  • Division 03 — Concrete
  • Division 04 — Masonry
  • Division 05 — Metals
  • Division 06 — Wood, Plastics, and Composites
  • Division 07 — Thermal and Moisture Protection
  • Division 08 — Openings
  • Division 09 — Finishes
  • Division 10 — Specialties
  • Division 11 — Equipment
  • Division 12 — Furnishings
  • Division 13 — Special Construction
  • Division 14 — Conveying Equipment
  • Division 15 — RESERVED FOR FUTURE EXPANSION
  • Division 16 — RESERVED FOR FUTURE EXPANSION

Facility Services Subgroup

  • Division 20 — RESERVED FOR FUTURE EXPANSION
  • Division 21 — Fire Suppression
  • Division 22 — Plumbing
  • Division 23 — Heating Ventilating and Air Conditioning
  • Division 24 — RESERVED FOR FUTURE EXPANSION
  • Division 25 — Integrated Automation
  • Division 26 — Electrical
  • Division 27 — Communications
  • Division 28 — Electronic Safety and Security
  • Division 29 — RESERVED FOR FUTURE EXPANSION

Site and Infrastructure Subgroup

  • Division 30 — RESERVED FOR FUTURE EXPANSION
  • Division 31 — Earthwork
  • Division 32 — Exterior Improvements
  • Division 33 — Utilities
  • Division 34 — Transportation
  • Division 35 — Waterways and Marine Construction
  • Division 36 — RESERVED FOR FUTURE EXPANSION
  • Division 37 — RESERVED FOR FUTURE EXPANSION
  • Division 38 — RESERVED FOR FUTURE EXPANSION
  • Division 39 — RESERVED FOR FUTURE EXPANSION

Process Equipment Subgroup

  • Division 40 — Process Integration
  • Division 41 — Material Processing and Handling Equipment
  • Division 42 — Process Heating, Cooling, and Drying Equipment
  • Division 43 — Process Gas and Liquid Handling, Purification and Storage Equipment
  • Division 44 — Pollution Control Equipment
  • Division 45 — Industry-Specific Manufacturing Equipment
  • Division 46 — RESERVED FOR FUTURE EXPANSION
  • Division 47 — RESERVED FOR FUTURE EXPANSION
  • Division 48 — Electrical Power Generation
  • Division 49 — RESERVED FOR FUTURE EXPANSION

Master-Format Subgroups

Division 22 Plumbing

  • 22 00 00 Plumbing
  • 22 10 00 Plumbing Piping and Pumps
  • 22 20 00 Unassigned
  • 22 30 00 Plumbing Equipment
  • 22 40 00 Plumbing Fixtures
  • 22 50 00 Pool and Fountain Plumbing Systems
  • 22 60 00 Gas and Vacuum Systems for Labatory and Healtcare Facilities
  • 22 70 00 Unassigned
  • 22 80 00 Unassigned
  • 22 90 00 Unassigned

Division 26 Electrical

  • 26 00 00 Electrical 
  • 26 10 00 Medium-Voltage Electrical Distribution
  • 26 20 00 Low-Voltage Electrical Distribution
  • 26 30 00 Facility Electrical Power Generating and Storing Equipment
  • 26 40 00 Electrical and Cathodic Protection
  • 26 50 00 Lighting
  • 26 60 00 Unassigned
  • 26 70 00 Unassigned
  • 26 80 00 Unassigned
  • 26 90 00 Unassigned

Division 27 Communications

  • 27 00 00 Communications
  • 27 10 00 Structured Cabling
  • 27 20 00 Data Communications
  • 27 30 00 Voice Communications
  • 27 40 00 Audio-Video Communications
  • 27 50 00 Distributed Communications and Monitoring Systems
  • 27 60 00 Unassigned
  • 27 70 00 Unassigned
  • 27 80 00 Unassigned
  • 27 90 00 Unassigned

Division 28 Electronic Safety and Security

  • 28 00 00 Electronic Safety and Security
  • 28 10 00 Electronic Access Control and Intrusion Detection
  • 28 20 00 Electronic Surveillance
  • 28 30 00 Electronic Detection and Alarm
  • 28 40 00 Electronic Monitoring and Control
  • 28 50 00 Unassigned
  • 28 60 00 Unassigned
  • 28 70 00 Unassigned
  • 28 80 00 Unassigned
  • 28 90 00 Unassigned

Division 33 Utilities

  • 33 70 00 Electrical Utilities
  • 33 80 00 Communications Utilities
  • 33 90 00 Unassigned

Unit Converter


















































6.29.10



3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!