Sound Pressure Level - OSHA A-Weighted per Day
Maximum A-weighted sound pressure levels allowed by the U.S. Occupational Safety and Health Administration - OSHA - for periods in a working day:
| Duration per Day (hr) | Maximum Allowed Sound Pressure Level (dBA) |
|---|---|
| 8 | 90 |
| 6 | 92 |
| 4 | 95 |
| 3 | 97 |
| 2 | 100 |
| 1.5 | 102 |
| 1 | 105 |
| 0.5 | 110 |
| less than 0.25 | 115 |
Download and print Maximum Allowable Sound Pressure Level per Day chart
Related Topics
• Acoustics
Room acoustics and acoustic properties. decibel A, B and C calculations. Noise Rating (NR) curves. Sound transmission through walls. Calculate sound pressure, sound intensity and sound attenuation.
Related Documents
Maximum Sound Pressure Levels in Rooms
Maximum recommended sound pressure levels in rooms like kindergartens, auditoriums, libraries, cinemas and more.
Noise - Acceptable dBA Level
Acceptable noise - dBA - level at typical common locations.
Noise - Recommended Exposure Limits (REL)
The NIOSH noise Recommended Exposure Limit - REL - for occupational noise
RC - the Room Criteria
The Room Criteria (RC) is used to measure background noise in buildings for frequencies ranging 16 to 4000 Hz.
Sound - Ldn - Day and Night Level
The EPA A-weighted sound level day and night equivalent definition - Ldn - for a 24 hour period.
Sound - Leq - Equivalent Level
The EPA Equivalent Sound Level - Leq - quantifies the noise environment to a single value of sound level for any desired duration.
Sound - Ls - Exposure Level
The EPA Sound Exposure Level - Ls - describes the noise from a variable source.
Sound Pressure Level
Sound Pressure is the force of sound on a surface perpendicular to the propagation of sound.