| Material | Density | |||
| (lbs/ft3) | (lbs/ft3) | (kg/m3) | (kg/m3) | |
| ABS resin, pellet | 45 | - | 721 | - |
| Acetic acid, liquid | 66 | - | - | - |
| Acetone | 49 | - | 785 | - |
| Acrylic resin | 33 | - | - | - |
| Adipic acid, powder | 45 | - | 721 | - |
| Alcohol, ethyl | 56 | - | - | - |
| Alcohol, methyl | 49 | - | 785 | - |
| Alfalfa, ground | 16 | - | - | - |
| Almonds, shelled | 30 | 35 | 481 | 561 |
| Alum powder | 50 | - | - | - |
| Alumina | 60 | - | 961 | - |
| Aluminum hydrate | 18 | - | - | - |
| Aluminum oxide | 60 | 100 | 961 | 1602 |
| Aluminum silicate | 35 | 45 | - | 721 |
| Aluminum, powder | 45 | 80 | 721 | 1281 |
| Aluminum, shavings | 7 | 15 | - | 240 |
| Ammonium nitrate, prill | 45 | 60 | 721 | 961 |
| Ammunium sulphate | 40 | 58 | - | 929 |
| Apple seed | 32 | - | 513 | - |
| Asbestos fibers | 20 | 25 | - | 400 |
| Ash, coal, damp | 45 | 50 | 721 | 801 |
| Ash, coal, dry | 35 | 45 | - | 721 |
| Asphalt, liquid | 65 | - | 1041 | - |
| Aviation fuel (jp-4) | 49 | - | - | - |
| Bakalite, powder | 30 | 40 | 481 | 641 |
| Baking powder | 40 | 45 | - | 721 |
| Baking soda | 70 | 80 | 1121 | 1281 |
| Ball clay | 25 | - | - | - |
| Bagasse - exiting the final mill | 7.5 | - | 120 | - |
| Bagasse - stacked to 2 metre height (moisture = 44%) | 11 | - | 176 | - |
| Bark, wood refuse | 10 | 20 | 160 | 320 |
| Barley, flour | 25 | 30 | - | 481 |
| Barley, ground | 25 | 30 | 400 | 481 |
| Barley, kernal | 35 | 40 | - | 641 |
| Barley, malted | 31 | - | 497 | - |
| Bauxite, crushed | 75 | 85 | - | 1362 |
| Beans, caster | 36 | - | 577 | - |
| Beans, coffee | 22 | 40 | - | 641 |
| Beans, lima | 45 | - | 721 | - |
| Beans, navy | 48 | - | - | - |
| Beans, soy | 45 | 47 | 721 | 753 |
| Bentonite, lump | 25 | 40 | - | 641 |
| Bentonite, powder | 50 | 60 | 801 | 961 |
| Bicarbonate of soda | 41 | - | - | - |
| Blood, dry | 35 | 45 | 561 | 721 |
| Bone meal | 55 | 60 | - | 961 |
| Borate of lime | 50 | 70 | 801 | 1121 |
| Borax | 50 | 70 | - | 1121 |
| Boric acid powder | 55 | - | 881 | - |
| Bran, oat | 25 | - | - | - |
| Bran, wheat | 15 | 20 | 240 | 320 |
| Brewers grain | 27 | - | - | - |
| Brewers grits | 33 | - | 529 | - |
| Bronze chips | 30 | 50 | - | 801 |
| Buckwheat | 34 | 42 | 545 | 673 |
| Buckwheat flour | 40 | - | - | - |
| Butter | 54 | - | 865 | - |
| Buttermilk powder | 25 | 30 | - | 481 |
| Cake mix | 30 | 40 | 481 | 641 |
| Calcium carbide | 75 | - | - | - |
| Calcium carbonate | 75 | - | 1201 | - |
| Calcium oxide | 27 | - | - | - |
| Cane - whole stick, tangled and tamped down as in a cane transport vehicle | 12.5 | - | 200 | - |
| Cane - whole stick, neatly bundled | 25 | - | 400 | - |
| Cane - billetted | 22 | - | 352 | - |
| Cane - whole stick tangled, but loosely tipped into cane carrier | 10 | - | 160 | - |
| Cane - knifed | 18 | - | 288 | - |
| Cane - shredded | 20 | - | 320 | - |
| Carbide powder | 100 | - | 1602 | - |
| Carbon black powder | 4 | 25 | - | 400 |
| Carbon black, pellet | 20 | 45 | 320 | 721 |
| Carbon tetrachloride | - | - | - | - |
| Carbon, granulated, activated | 50 | 60 | 801 | 961 |
| Carbon, graphite | 40 | - | - | - |
| Casein powder | 35 | 40 | 561 | 641 |
| Cashew nuts | 32 | 37 | - | 593 |
| Caster beans | 36 | - | 577 | - |
| Cat food | 20 | 25 | - | 400 |
| Cellophane, flocking | 5 | - | 80 | - |
| Cellulose acetate | 10 | - | - | - |
| Cellulose, flocking | 1.5 | 3 | 24 | 48 |
| Cement powder, portland | 85 | 95 | - | 1522 |
| Cement, clinker | 75 | 90 | 1201 | 1442 |
| Cereal flake | 12 | - | - | - |
| Chalk, fine | 70 | 75 | 1121 | 1201 |
| Chalk, lump | 85 | 90 | - | 1442 |
| Charcoal | 15 | 30 | 240 | 481 |
| Chromium ore | 135 | - | - | - |
| Cinders, coal | 40 | 50 | 641 | 801 |
| Citric acid | 55 | - | - | - |
| Clay, attapulgus | 55 | - | 881 | - |
| Clay, ball | 25 | - | - | - |
| Clay, bentonite | 51 | - | 817 | - |
| Clay, calcined | 80 | - | - | - |
| Clay, dicalite | 20 | 50 | 320 | 801 |
| Clay, kaoline | 20 | 60 | - | 961 |
| Clay, sno-brite | 15 | 50 | 240 | 801 |
| Clay, whitex | 15 | 50 | - | 801 |
| Clinker, cement | 80 | - | 1281 | - |
| Clinker, coal | 80 | 90 | - | 1442 |
| Coal, ground | 40 | - | 641 | - |
| Coal, lump | 45 | 55 | - | 881 |
| Coconut, shredded | 20 | 22 | 320 | 352 |
| Coffee bean, green | 32 | 45 | - | 721 |
| Coffee bean, roasted | 22 | 30 | 352 | 481 |
| Coffee, ground | 20 | - | - | - |
| Coke, calcined, petrol | 35 | 45 | 561 | 721 |
| Copper ore | 135 | - | - | - |
| Copper oxide | 190 | - | 3043 | - |
| Cork, ground | 5 | 15 | - | 240 |
| Corn bran | 13 | - | 208 | - |
| Corn cob, ground | 35 | - | - | - |
| Corn, cracked | 35 | 40 | 561 | 641 |
| Corn, flaked | 6 | - | - | - |
| Corn, gern | 21 | - | 336 | - |
| Corn, gluten | 26 | 33 | - | 529 |
| Corn, grits | 40 | 45 | 641 | 721 |
| Corn, ground | 30 | 35 | - | 561 |
| Corn, meal | 32 | 40 | 513 | 641 |
| Corn, starch | 25 | 35 | - | 561 |
| Corn, sugar, liquid | 88 | - | 1410 | - |
| Corn, sugar, powder | 31 | - | - | - |
| Corn, whole kernel | 45 | - | 721 | - |
| Cotton blossoms | 15 | 25 | - | 400 |
| Cottonseed | 22 | 40 | 352 | 641 |
| Cottonseed hulls | 12 | - | - | - |
| Cottonseed meats | 40 | - | 641 | - |
| Cottonseed oil | 58 | - | - | - |
| Cottonseed, meal | 35 | 40 | 561 | 641 |
| Cream powder | 38 | - | - | - |
| Cullett, glass | 120 | - | 1922 | - |
| Dextrin | 50 | 55 | - | 881 |
| Dextrose | 31 | - | 497 | - |
| Diatomacaous earth | 11 | 14 | - | 224 |
| Dicalcium phosphate | 43 | - | 689 | - |
| Diesel fuel | 52 | - | - | - |
| Dirt, dry | 65 | 80 | 1041 | 1281 |
| Distillars grain | 30 | - | - | - |
| Dog food, IAMS minichunk | 26 | - | 416 | - |
| Dolomite, lump | 88 | 99 | - | 1586 |
| Dolomite, powdered | 45 | - | 721 | - |
| Down, goose | 1 | - | - | - |
| Ebonite, crushed | 65 | 70 | 1041 | 1121 |
| Emery, crushed | 95 | - | - | - |
| Epsom salt | 40 | 50 | 641 | 801 |
| Ethanol | 56 | - | - | - |
| Ethyl ether | 44 | - | 705 | - |
| Ethylene glycol | 70 | - | - | - |
| Expancel microsphere | 0.8 | - | 13 | - |
| Farina | 44 | - | - | - |
| Feathers, goose | 1 | - | 16 | - |
| Feed pellets, animal | 32 | 38 | - | 609 |
| Feldspar, ground | 65 | 70 | 1041 | 1121 |
| Ferrous sulphate | 50 | 75 | - | 1201 |
| Fertilizer, phosphate | 60 | - | 961 | - |
| Fish meal | 25 | 40 | - | 641 |
| Flax seed | 40 | 45 | 641 | 721 |
| Flour, barley | 25 | 30 | - | 481 |
| Flour, corn | 30 | 34 | 481 | 545 |
| Flour, patent | 20 | - | - | - |
| Flour, wheat | 30 | 35 | 481 | 561 |
| Flourospar | 90 | - | - | - |
| Fluff, poly-fim floc | 1.5 | 2 | 24 | 32 |
| Fly ash | 35 | 45 | - | 721 |
| Froot loops, kellogs | 8 | - | 128 | - |
| Fullers earth | 35 | 45 | - | 721 |
| Gasoline | 45 | - | 721 | - |
| Gelatine, granulated | 32 | - | - | - |
| Gilsonite | 37 | - | 593 | - |
| Glass bead | 120 | - | - | - |
| Glass cullett crushed | 120 | - | 1922 | - |
| Gluten, wheat | 30 | 35 | - | 561 |
| Glycerine | 78 | - | 1249 | - |
| Golf tees | 15 | - | - | - |
| Graphite, ground | 25 | 30 | 400 | 481 |
| Grass seed | 10 | 35 | - | 561 |
| Gravel | 75 | 85 | 1201 | 1362 |
| Grits, corn | 40 | 45 | - | 721 |
| Grits, rice | 42 | 45 | 673 | 721 |
| Gun powder | 50 | - | - | - |
| Gypsum, lump | 90 | 100 | 1442 | 1602 |
| Gypsum, powder | 60 | 80 | - | 1281 |
| Hay | 5 | 24 | 80 | 384 |
| HDPE, polethylene | 35 | 40 | - | 641 |
| Hominey | 37 | 50 | 593 | 801 |
| Hops | 35 | - | - | - |
| Hops, spent dry | 35 | - | 561 | - |
| Hydrochloric acid | 75 | - | - | - |
| Ice, crushed | 55 | - | 881 | - |
| Illmenite, ground | 120 | - | - | - |
| Iron chips | 165 | - | 2643 | - |
| Iron ore | 150 | - | - | - |
| Iron oxide | 180 | - | 2883 | - |
| Jet fuel, jp4 | 51 | - | - | - |
| Kafir | 40 | 45 | 641 | 721 |
| Kalsomine, powder | 32 | - | - | - |
| Kaoline, crushed | 20 | 22 | 320 | 352 |
| Kerosene | 51 | - | - | - |
| Lactose | 32 | - | 513 | - |
| LDPE, polyethylene | 35 | - | - | - |
| Lead oxide | 30 | 150 | 481 | 2403 |
| Liginite | 40 | 55 | - | 881 |
| Lima beans dry | 45 | - | 721 | - |
| Lime, hydreated | 25 | 30 | - | 481 |
| Lime, pebble | 55 | 65 | 881 | 1041 |
| Lime, quicklime | 25 | 30 | - | 481 |
| Lime, slaked | 32 | - | 513 | - |
| Limestone, crushed | 85 | 95 | - | 1522 |
| Limestone, dust | 68 | - | 1089 | - |
| Linseed oil | 58 | - | - | - |
| Linseed, kernel | 25 | - | 400 | - |
| Maize, kernel | 45 | - | - | - |
| Malt sugar | 30 | 35 | 481 | 561 |
| Malt, dry, whole | 30 | 35 | - | 561 |
| Malt, ground, dry | 20 | - | 320 | - |
| Malt, spent, damp | 55 | 65 | - | 1041 |
| Malt, spent, dry | 10 | - | 160 | - |
| Maltodextrin powder | 35 | - | - | - |
| Maple syrup | 85 | - | 1362 | - |
| Marble, crushed | 85 | 95 | - | 1522 |
| Menthol | 49 | - | 785 | - |
| Metal dust | 50 | 120 | - | 1922 |
| Methanol | 49 | - | 785 | - |
| Methyl alcohol | 49 | - | - | - |
| Mica | 13 | 30 | 208 | 481 |
| Milk powder | 15 | 20 | - | 320 |
| Milk sugar | 32 | - | 513 | - |
| Miller, ground | 35 | - | - | - |
| Millet seed | 48 | - | 769 | - |
| Mineral oil | 57 | - | - | - |
| Mineral spirits | 49 | - | 785 | - |
| Molybdenum, floc | 10 | 12 | - | 192 |
| Monosodium phosphate | 50 | - | 801 | - |
| Muriate of potash | 77 | - | - | - |
| Mustard seed | 45 | - | 721 | - |
| Naphthalene | 56 | - | - | - |
| Napthalene flakes | 45 | - | 721 | - |
| Navy beans, dry | 48 | - | - | - |
| Nitrate of soda | 68 | - | 1089 | - |
| Nitric acid | 94 | - | - | - |
| Nitrocellulose | 25 | - | 400 | - |
| Nylon | 35 | 45 | - | 721 |
| Oat flour | 30 | 35 | 481 | 561 |
| Oat hulls | 8 | 12 | - | 192 |
| Oat meal | 35 | 40 | 561 | 641 |
| Oat middlings | 35 | 45 | - | 721 |
| Oats | 25 | 35 | 400 | 561 |
| Oats, bran | 25 | - | - | - |
| Oats, ground | 25 | 30 | 400 | 481 |
| Oats, rolled | 24 | - | - | - |
| Octane | 45 | - | 721 | - |
| Oil, linseed | 58 | - | - | - |
| Oil, olive | 57 | - | 913 | - |
| Oil, petroleum, crude | 53 | - | - | - |
| Oil, sperm whale | 57 | - | 913 | - |
| Oil, transformer | 55 | - | - | - |
| Oil, turpentine | 54 | - | 865 | - |
| Oxalic acid, crystals | 60 | - | - | - |
| Oyster shells, ground | 53 | - | 849 | - |
| Paper, shreaded | 5 | 12 | - | 192 |
| Paraffin wax | 45 | - | 721 | - |
| PC, polycarbonate | 34 | 36 | - | 577 |
| Peanut shell refuse | 4 | - | 64 | - |
| Peanuts, shelled | 35 | 45 | - | 721 |
| Peanuts, unshelled | 15 | 24 | 240 | 384 |
| Peas, dry | 45 | 50 | - | 801 |
| Peat | 25 | 50 | 400 | 801 |
| Perlite, expanded | 3 | - | - | - |
| Petroleum oil | 51 | - | 817 | - |
| Phosphate rock, crushed | 60 | 80 | - | 1281 |
| Phosphate sand | 90 | 100 | 1442 | 1602 |
| Plaster of Paris | 50 | 55 | - | 881 |
| Plastic pellet | 34 | 48 | 545 | 769 |
| Ployethylene, pellet | 34 | 36 | - | 577 |
| Ployvinyl chloride, powder | 30 | - | 481 | - |
| Polyethylene pellet | 35 | 37 | - | 593 |
| Polypropylene powder | 25 | - | 400 | - |
| Polypropylene, pellet | 34 | 36 | - | 577 |
| Polystyrene, expanded beads | 1.5 | - | 24 | - |
| Polystyrene, pellet | 40 | - | - | - |
| Polyvinyl chloride, pellet | 48 | 52 | 769 | 833 |
| Popcorn, popped | 2-3 | - | - | - |
| Popcorn, shelled | 45 | 50 | 721 | 801 |
| Potash | 50 | 60 | - | 961 |
| Potasium chloride | 2 | 3 | 32 | 48 |
| Potassium carbonate | 45 | 50 | - | 801 |
| Potassium chloride | 75 | - | 1201 | - |
| Potassium nitrate | 76 | - | - | - |
| Potassium sulphate | 42 | 48 | 673 | 769 |
| Potato flake | 12 | - | - | - |
| Potato starch | 40 | - | 641 | - |
| Pumice | 40 | 45 | - | 721 |
| PVC polyvinyl chloride | 48 | 52 | 769 | 833 |
| Quartz, sand | 80 | 100 | - | 1602 |
| Rape seed | 45 | 50 | 721 | 801 |
| Rice | 45 | 50 | - | 801 |
| Rice bran | 20 | - | 320 | - |
| Rice flour | 30 | - | - | - |
| Rice grits | 42 | 45 | 673 | 721 |
| Rubber, ground | 25 | 50 | - | 801 |
| Rye | 44 | - | 705 | - |
| Rye, flour | 30 | - | - | - |
| Salt, coarse crushed | 45 | 55 | 721 | 881 |
| Salt, granulated | 70 | 80 | - | 1281 |
| Saltpeter | 75 | - | 1201 | - |
| Sand, damp | 100 | - | - | - |
| Sand, dry | 80 | 100 | 1281 | 1602 |
| Sand, loose | 90 | - | 1442 | - |
| Sand with gravel, dry | 108 | - | 1650 | - |
| Sand with gravel, wet | 125 | - | 2020 | - |
| Sand, rammed | 105 | - | 1682 | - |
| Sand, silica | 95 | - | - | - |
| Sand, water filled | 120 | - | 1922 | - |
| Sand, wet | 120 | - | 1922 | - |
| Sand, wet, packed | 130 | - | 2082 | - |
| Sandstone, crushed | 80 | 95 | 1281 | 1522 |
| Sawdust | 4 | 12 | - | 192 |
| Sea water | 64 | - | 1025 | - |
| Semolina | 35 | 40 | - | 641 |
| Sesame seed | 27 | 37 | 432 | 593 |
| Shellac powder | 30 | 35 | - | 561 |
| Silica flour | 35 | 40 | 561 | 641 |
| Silica gel | 30 | 45 | - | 721 |
| Silica sand | 95 | - | 1522 | - |
| Slag, furnace | 60 | - | - | - |
| Slakes lime | 32 | - | 513 | - |
| Slate, crushed | 80 | 90 | - | 1442 |
| Soap powder | 20 | 25 | 320 | 400 |
| Soda ash | 30 | 45 | - | 721 |
| Sodium bicarbonate | 41 | - | 657 | - |
| Sodium chloride | 70 | - | - | - |
| Sodium hydroxide, flake | 47 | - | 753 | - |
| Sodium nitrate | 68 | 80 | - | 1281 |
| Sodium sulphate | 80 | - | 1281 | - |
| Sorghum seed | 42 | 50 | - | 801 |
| Soybean flour | 27 | 35 | 432 | 561 |
| Soybean hulls | 6 | - | - | - |
| Soybean meal | 36 | 50 | 577 | 801 |
| Soybean, flakes | 18 | 25 | - | 400 |
| Soybean, whole | 47 | - | 753 | - |
| Soybeean, cracked | 35 | - | - | - |
| Spelt flour | 25 | 30 | 400 | 481 |
| Starch powder | 25 | 35 | - | 561 |
| Steel, chips | 150 | - | 2403 | - |
| Sucrose - crystal | 99 | - | 1586 | - |
| Sucrose - amorphous | 94 | - | 1507 | - |
| Sugar, brown | 45 | - | 721 | - |
| Sugar, dextrose, powder | 50 | - | - | - |
| Sugar, granulated | 53 | - | 849 | - |
| Sugar, milk | 32 | - | - | - |
| Sugar, powdered | 50 | 60 | 801 | 961 |
| Sugar, raw | 55 | 65 | - | 1041 |
| Sulfuric acid | 112 | - | 1794 | - |
| Sulphur, crushed | 55 | 70 | - | 1121 |
| Sunflower seed | 36 | - | 577 | - |
| Talcum powder | 4 | 62 | - | 993 |
| Tar | 72 | - | 1153 | - |
| Tea leaves | 12 | - | - | - |
| Terephalic acid powder | 45 | - | 721 | - |
| Timothy seed | 36 | - | - | - |
| Tin oxide | 100 | - | 1602 | - |
| Titanium dioxide | 40 | 50 | - | 801 |
| Tobacco, flake | 2 | 5 | 32 | 80 |
| Toulene | 54 | - | - | - |
| Transmission oil | 54 | - | 865 | - |
| Trisodium phosphate | 50 | 60 | - | 961 |
| Urea, prill | 34 | 42 | 545 | 673 |
| Vermiculite ore | 80 | - | - | - |
| Vermiculite, expanded | 17 | - | 272 | - |
| Walnut meats | 25 | - | - | - |
| Walnut shells, ground | 40 | 45 | 641 | 721 |
| Water | 62 | - | - | - |
| Wax | 15 | 20 | 240 | 320 |
| Wheat bran | 12 | - | - | - |
| Wheat gluten | 30 | 35 | 481 | 561 |
| Wheat, craked | 35 | 45 | - | 721 |
| Wheat, flaked | 7 | 10 | 112 | 160 |
| Wheat, flour | 30 | 35 | - | 561 |
| Wheat, ground | 40 | - | 641 | - |
| Wheat, whole kernel | 45 | 55 | - | 881 |
| Whey powder | 35 | 46 | 561 | 737 |
| Wood chips | 20 | 30 | - | 481 |
| Wood flour | 15 | 25 | 240 | 400 |
| Wood shavings | 3 | 10 | - | 160 |
| Xanthum gum | 48 | - | 769 | - |
| Zinc ore | 125 | - | - | - |
| Zinc oxide | 10 | 30 | 160 | 481 |
| Zinc, calcined, crushed | 70 | 90 | - | 1442 |