Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Cast Iron Flanges - Stud Reference Chart

The number, diameter and length of studs for cast iron flanges class 125 and 250.

The studs sizes for cast iron flanges class 125 and 250 are indicated in the tables below. The sizes are for standard facing and standard pressure ratings flange to flange.

Cast Iron Flanges - Class 125

Cast Iron Flanges - Stud Reference Chart - Class 125
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 2-1/2
3/4 4 1/2 2-1/2
1 4 1/2 2-3/4
1-1/4 4 1/2 2-3/4
1-1/2 4 1/2 3
2 4 5/8 3-1/2
2-1/2 4 5/8 3-3/4
3 4 5/8 3-3/4
3-1/2 8 5/8 3-3/4
4 8 5/8 3-3/4
5 8 3/4 4
6 8 3/4 4-1/4
8 8 3/4 4-1/2
10 12 7/8 4-3/4
12 12 7/8 5
14 12 1 5-1/2
16 16 1 5-1/2
  • 1 inch = 25.4 mm

Cast Iron Flanges - Class 250

Cast Iron Flanges - Stud Reference Chart - Class 250
NPS
(in)
No. of
Studs
Diameter of Stud
(in)
Length of Stud
(in)
1/2 4 1/2 2-3/4
3/4 4 5/8 3-1/4
1 4 5/8 3-1/4
1-1/4 4 5/8 3-1/2
1-1/2 4 5/8 3-3/4
2 8 5/8 3-3/4
2-1/2 8 5/8 4-1/4
3 8 5/8 4-1/2
3-1/2 8 5/8 4-1/2
4 8 5/8 4-3/4
5 8 5/8 5
6 12 5/8 5
8 12 7/8 5-3/4
10 16 1 6-1/2
12 16 1-1/8 7
14 20 1-1/8 7-1/4
16 20 1-1/4 7-3/4
18 24 1-1/4 8

Unit Converter


















































6.29.10



3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!