Malleable Iron Threaded Fittings - Pressure and Temperature Ratings
ASME/ANSI B16.3 - 1998 - Malleable Iron Threaded Fittings - Pressure and Temperature Ratings
This Standard for threaded malleable iron fittings Classes 150, and 300 provides requirements for the following:
- (a) pressure-temperature ratings
- (b) size and method of designating openings of reducing fittings
- (c) marking
- (d) materials
- (e) dimensions and tolerances
- (f) threading
- (g) coatings
Pressure-temperature ratings can be found in the table below:
Pressure-Temperature ratings for malleable iron threaded fittings (psig) | |||||
---|---|---|---|---|---|
Temperature | Class | ||||
150 | 300 | ||||
1/4 - 1 inches | 1 1/4 - 2 inches | 2 1/2 - 3 inches | |||
(oF) | (oC) | ||||
-20 to 150 | -29 to 66 | 300 | 2000 | 1500 | 1000 |
200 | 93 | 265 | 1785 | 1350 | 910 |
250 | 121 | 225 | 1575 | 1200 | 825 |
300 | 149 | 185 | 1360 | 1050 | 735 |
350 | 177 | 150 | 1150 | 900 | 650 |
400 | 204 | - | 935 | 750 | 560 |
450 | 232 | - | 725 | 600 | 475 |
500 | 260 | - | 510 | 450 | 385 |
550 | 288 | - | 300 | 300 | 300 |
- 1 psi = 0.0689 bar = 6.89 kPa