Air Properties - SI Units
Ideal gas properties of air at low pressures - in SI units
Ideal gas properties for air at low pressure:
Temperature - T - (K) | Enthalpy - h - (kJ/kg) | Relative Pressure - pr - | Internal Energy - u - (kJ/kg) | Specific Volume - vr - |
---|---|---|---|---|
200 | 200 | 0.336 | 143 | 1707 |
250 | 250 | 0.733 | 178 | 979 |
300 | 300 | 1.39 | 214 | 621 |
350 | 350 | 2.38 | 250 | 422 |
400 | 401 | 3.81 | 286 | 302 |
450 | 452 | 5.76 | 323 | 224 |
500 | 503 | 8.41 | 359 | 171 |
550 | 555 | 11.9 | 397 | 133 |
600 | 607 | 16.3 | 435 | 106 |
650 | 660 | 21.9 | 473 | 85 |
700 | 713 | 28.8 | 512 | 70 |
750 | 767 | 37.4 | 552 | 58 |
800 | 822 | 47.8 | 592 | 48 |
900 | 933 | 75.3 | 675 | 34.3 |
1000 | 1046 | 114 | 759 | 25.2 |
1100 | 1161 | 167 | 845 | 18.9 |
1200 | 1278 | 238 | 933 | 14.5 |
1300 | 1396 | 331 | 1023 | 11.3 |
1400 | 1515 | 451 | 1114 | 8.9 |
1500 | 1636 | 602 | 1205 | 7.2 |
1600 | 1758 | 791 | 1298 | 5.8 |
1700 | 1880 | 1025 | 1392 | 4.8 |
1800 | 2003 | 1310 | 1487 | 3.9 |
1900 | 2127 | 1655 | 1583 | 3.3 |
2000 | 2252 | 2068 | 1679 | 2.8 |
2100 | 2377 | 2559 | 1775 | 2.4 |
2200 | 2503 | 3138 | 1872 | 2.0 |