ANSI/ASME B1.5 - ACME Screw Threads

Acme trapezoidal threads.

ACME trapezoidal thread screw

Acme thread dimensions:

ANSI/ASME B1.5 - ACME Screw Threads
Outside Diameter Screw
(in)
TPIInside Diameter Nut
(in)
Crest Nut
(in)
Outside Clearance
(in)
Inside Clearance
(in)
Fit Allowance
(in)
1/4 16 0.187 0.023 0.005 0.005 0.0010
5/16 14 0.241 0.026 0.005 0.005 0.0010
3/8 12 0.275 0.037 0.010 0.010 0.0013
7/16 12 0.337 0.037 0.010 0.010 0.0013
1/2 10 0.400 0.037 0.010 0.010 0.0015
5/8 8 0.500 0.046 0.010 0.010 0.0016
3/4 6 0.583 0.062 0.010 0.010 0.0018
7/8 6 0.708 0.062 0.010 0.010 0.0019
1 6 0.833 0.062 0.010 0.010 0.0021

The ANSI/ASME B1.5 ACME Screw Threads Standard provides

  • General Purpose ACME, and
  • Centralizing ACME

Centralizing Acme threads have limited clearance at the major diameters of both the internal and external threads and are used extensively for feed screws. Restricted clearance enables a bearing at the major diameter of the thread to preserve alignment of the thread axis preventing wedging on the flanks and part sagging.