Custom Search
A table with the enthalpy of steam superheated to temperatures above the boiling point with corresponding temperatures
The table below can be used to find superheated steam enthalpy at
different pressures and temperatures.
| Enthalpy of Superheated Steam (kJ/kg) |
Pressure
(bar) |
Saturation Temperature
(oC) |
Temperature (oC) |
| Saturation |
200 |
250 |
300 |
350 |
400 |
450 |
| 15 |
198.3 |
2792 |
2796 |
2925 |
3039 |
3148 |
3256 |
3364 |
| 20 |
212.4 |
2799 |
|
2904 |
3025 |
3138 |
3248 |
3357 |
| 30 |
233.8 |
2809 |
|
2858 |
2995 |
3117 |
3231 |
3343 |
| 40 |
250.3 |
2801 |
|
|
2963 |
3094 |
3214 |
3330 |
Search the Engineering ToolBox
Custom Search
Related Topics
Related Documents
-
Entropy of Superheated Steam
- A table with the entropy of steam superheated to temperatures above the boiling point with corresponding temperatures
-
Properties of Saturated Steam - Pressure in Bar
- The Saturated Steam Table with properties as boiling point, specific volume, density, specific enthalpy, specific heat and latent heat of vaporization
-
Steam and Vapor Enthalpy
- Introduction and definition of vapor and steam enthalpy - specific enthalpy of saturated liquid, saturated vapor and superheated vapor
Translate the Engineering ToolBox
About the EngineeringToolbox
Advertise in the Engineering ToolBox