This table can be used for estimating the steam consumption in the preliminary design of steam applications. Remember always check the manufacturing specifications before final design.
| Industry | Application | Operating Pressure | Consumption production | Consumption maximum | |||
| psig | bar | lb/h | kg/h | lb/h | kg/h | ||
| Bakeries | Dough room trough, 8 ft long | 10 | 1 | 5 | 2 | ||
| Proof Boxes, 500 cu ft capacity | 10 | 1 | 10 | 5 | |||
| Ovens | 0 | 0 | |||||
| White bread, 120 sq ft surface | 10 | 1 | 30 | 14 | |||
| Rye bread, 10 sq ft surface | 10 | 1 | 60 | 27 | |||
| Breweries | Bottle washing, normal size 100 bottles/min | 5 | 0.3 | 300 | 136 | ||
| Candy and Chocolate | Candy cooking, 30 gal cooker, 1 hour | 70 | 5 | 45 | 20 | ||
| Chocolate melting, jacketed, 24 inch diameter | 70 | 5 | 30 | 14 | |||
| Candy kettle per sq ft of jacket | 70 | 5 | 0 | 60 | 27 | ||
| Creameries and Dairies | Milk quarts per 100 cases per hr | 5 | 0.3 | 60 | 27 | ||
| Creamery cans 3 per min | 50 | 3 | 300 | 136 | |||
| Pasteurizer per 100 gal heated 20 min | 50 | 3 | 250 | 113 | |||
| Hospitals | tills per 100 gal distilled water | 50 | 3 | 100 | 45 | ||
| Sterilizers bed pan | 50 | 3 | 5 | 2 | |||
| Sterilizers instruments per 100 cu inch | 50 | 3 | 5 | 2 | |||
| Sterilizers water per 10 gal | 50 | 3 | 5 | 2 | |||
| Disinfecting ovens 100 cu ft, per 10 cu ft | 50 | 3 | 25 | 11 | |||
| Laundry | Vacuum stills per 10 gal | 100 | 7 | 15 | 7 | ||
| Spotting board | 100 | 7 | 30 | 14 | |||
| Jacket, dress finisher | 100 | 7 | 50 | 23 | |||
| Steam Irons | 100 | 7 | 5 | 2 | |||
| Flat iron worker, 48'' * 120'' | 100 | 7 | 300 | 136 | |||
| Plastic Molding | 12 to 15 sq ft platen surface | 125 | 9 | 30 | 14 | ||
| Paper Production | Corrugators per 1000 sq ft | 175 | 12 | 30 | 14 | ||
| Wood pulp paper per 10 lb paper | 50 | 3 | 400 | 181 | |||
| Restaurants | Dishwasher | 20 | 1 | 70 | 32 | ||
| Standard steam tables per ft length | 20 | 1 | 40 | 18 | |||
| Bain Marie per ft length 30 '' wide | 20 | 1 | 15 | 7 | |||
| Oyster steamers | 20 | 1 | 15 | 7 | |||
| Clam and lobster steamer | 20 | 1 | 30 | 14 | |||
| Steam jacket kettle 10 gal | 20 | 1 | 15 | 7 | 100 | 45 | |
| Steam jacket kettle 60 gal | 20 | 1 | 60 | 27 | 200 | 91 | |
| Plate and dish warmers per 100 sq ft | 20 | 1 | 60 | 27 | |||
| Warming ovens per 20 cu ft | 20 | 1 | 30 | 14 | |||
| Vegetable steamer | 20 | 1 | 30 | 14 | |||
| Potato Steamer | 20 | 1 | 30 | 14 | |||
| Tire Shops | Truck molds | 100 | 7 | 90 | 41 | ||
| Passenger molds | 100 | 7 | 30 | 14 | |||