Oil Viscosity Converter
Convert between commonly used oil viscosity units.
Convert between commonly used oil kinematic viscosity units :
Convert from | Multiply with | ||||
|---|---|---|---|---|---|
| Convert to | |||||
| Poise (P) | centiPoise (cP) | Reyn | Stoke (cm2/sec) | centiStoke | |
| Poise (P) | 1 | 100 | 1.45×10-5 | 1 / SG | 100 / SG |
| centiPoise (cP) | 0.01 | 1 | 1.45×10-7 | 0.01 / SG | 1 / SG |
| Reyn | 6.9×104 | 6.9×106 | 1 | 6.9×104/ SG | 6.9×106/ SG |
| Stoke (cm2/sec) |
SG | 100 SG | 1.45×10-5 SG | 1 | 100 |
| centiStoke | 0.01 SG | SG | 1.45×10-7 SG | 0.01 | 1 |
SG = specific gravity of the oil
1 Stoke = 100 mm2/second
Example - Convert Viscosity in Stokes to centiStoke
Oil with kinematic viscosity 0.1 Stoke (10 mm2/s) equals to
0.1 Stoke (100 centiStoke/Stoke) = 10 centiStokes