Chemical resistance of CPVC - Chlorinated Poly(Vinyl Chloride) - pipes
Recommended and not recommended chemicals in combination with CPVC -
Chlorinated Poly(Vinyl Chloride) - pipes are indicated below:
Chemicals Recommended
- Acetaldehyde, up to 10 %
- Acetaldehyde, >10%
- Acetaldehyde, pure
- Acetic Acid, up to 10%
- Acetic Acid, >10%
- Acetic Acid, pure
- Acetic Anhydride
- Acetone, up to 5%
- Acetone, >5%
- Acetone, pure
- Acetonitrile, up to 10%
- Acetonitrile, >10%
- Acetonitrile, pure
- Acetyl Chloride
- Acrylic Acid, aqueous
- Acrylic Acid, pure
- Acrylonitrile, aqueous
- Acrylonitrile, pure
- Adipic Acid
- Allyl Alcohol, aqueous
- Allyl Alcohol, pure
- Alum
- Aluminum Acetate
- Aluminum Chloride
- Aluminum Fluoride
- Aluminum Hydroxide
- Aluminum Nitrate
- Aluminum Sulfate
- Ammonia
- Ammonium Acetate
- Ammonium Benzoate
- Ammonium Bifuoride
- Ammonium Carbonate
- Ammonium Chloride
- Ammonium Citrate
- Ammonium Dichromate
- Ammonium Fluoride
- Ammonium Hydroxide
- Ammonium Metaphosphate
- Ammonium Nitrate
- Ammonium Persulfate
- Ammonium Phosphate
- Ammonium Sulfamate
- Ammonium Sulfate
- Ammonium Sulfde
- Ammonium Thiocyanate
- Ammonium Tartrate
- Amyl Alcohol, up to 1%
- Antimony Trichloride, aqueous
- Aqua Regia
- Arsenic Acid
- Aryl Sulfonic Acid
- Barium Carbonate
- Barium Chloride
- Barium Hydroxide
- Barium Nitrate
- Barium Sulfate
- Barium Sulfde
- Beer
- Beet Sugar Liquors
- Benzene Sulfonic Acid
- Benzoic Acid, aqueous
- Benzyl Alcohol
- Bismuth Carbonate
- Black Liquor
- Bleach
- Blood
- Borax
- Boric Acid
- Brine Acid
- Bromic Acid
- Bromine, liquid
- Bromine, aqueous
- Butanol, up to 1%
- Butanol, >1%
- Butanol, pure
- Butyl Carbitol
- Butyl Cellosolve
- Butyric Acid, up to 1%
- Butyric Acid, >1%
- Butyric Acid, pure
- Cadmium Acetate
- Cadmium Chloride
- Cadmium Cyanide
- Cadmium Sulfate
- Calcium Acetate
- Calcium Bisulfde
- Calcium Bisulfte
- Calcium Carbonate
- Calcium Chlorate
- Calcium Chloride
- Calcium Hydroxide
- Calcium Hypochlorite
- Calcium Nitrate
- Calcium Oxide
- Calcium Sulfate
- Cane Sugar Liquors
- Caprolactam, aqueous
- Caprolactone, aqueous
- Carbitol
- Carbolic Acid, up to 5%
- Carbolic Acid, >5%
- Carbolic Acid, pure
- Carbonic Acid
- Caustic Potash
- Caustic Soda
- Cellosolve
- Cellosolve Acetate
- Chloramine, aqueous
- Chloric Acid
- Chlorine, aqueous
- Chlorine dioxide, aqueous
- Chloroacetic Acid, up to 25%
- Chloroacetic Acid, >25%
- Chloroacetic Acid, pure
- Chromic Acid, 40%
- Chromium Nitrate
- Citric Acid
- Citrus Oils
- Coffee
- Copper Acetate
- Copper Carbonate
- Copper Chloride
- Copper Cyanide
- Copper Fluoride
- Copper Nitrate
- Copper Sulfate
- Corn Syrup
- Crotonaldehyde
- Cupric Fluoride
- Cupric Sulfate
- Cuprous Chloride
- Cyclohexane
- Cyclohexanol
- Cyclohexanone
- Decahydronaphthalene
- Detergents
- Dextrin
- Dextrose
- Diacetone Alcohol
- Dibutyl Ether
- Dichlorobenzene
- Diethylamine
- Diethyl Cellosolve
- Diethyl Ether
- Diglycolic Acid
- Dill Oil
- Dimethylamine
- Dimethylformamide
- Dimethylhydrazine
- Disodium Phosphate
- Dioxane, up to 30%
- Dioxane, >30%
- Dioxane, pure
- Distilled Water
- EDTA, Tetrasodium-
- Ethanol, up to 10%
- Ethanol, >10%
- Ethanol, pure
- Ethyl Acetate
- Ethyl Acetoacetate
- Ethyl Acrylate
- Ethyl Ether
- Ethyl Formate
- Ethyl Mercaptan
- Ethyl Oxalate
- Ethylene Glycol, up to 50%
- Ethylene Glycol, >50%
- Ethylene Oxide
- Ethylenediamine
- 2-ethylhexanol
- Ferric Chloride
- Ferric Hydroxide
- Ferric Nitrate
- Ferric Sulfate
- Ferrous Chloride
- Ferrous Hydroxide
- Ferrous Nitrate
- Ferrous Sulfate
- Fluoboric Acid
- Fluosilicic Acid
- Formaldehyde
- Formic Acid, up to 25%
- Formic Acid, >25%
- Formic Acid, pure
- Fructose
- Furfural
- Gallic Acid, aqueous
- Gasoline
- Gelatine
- Glucose
- Glycerine
- Glycolic Acid
- Glyoxal, aqueous
- Green Liquor
- Heptane
- Hexane
- Hexanol
- Hydrazine
- Hydrobromic Acid
- Hydrochloric Acid
- Hydrocyanic Acid
- Hydrofuoric Acid
- Hydrogen Peroxide, 10%
- Hydrogen Peroxide, 30%
- Hydrogen Peroxide, 50%
- Hydrogen Sulfde, aqueous
- Hydroquinone, aqueous
- Hydroxylamine Sulfate
- Hypochlorous Acid
- Iodine
- Isobutyl Alcohol
- Isophorone
- Isopropanol, up to 5%
- Isopropanol, >5%
- Isopropanol, pure
- Isopropyl Acetate
- Isopropyl Ether
- Kerosene
- Ketchup
- Kraft Liquors
- Lactic Acid
- Lead Acetate
- Lead Chloride
- Lead Nitrate
- Lead Sulfate
- Lemon Oil
- Ligroin
- Limonene
- Lithium Bromide
- Lithium Chloride
- Lithium Hydroxide
- Lithium Sulfate
- Magnesium Carbonate
- Magnesium Chloride
- Magnesium Citrate
- Magnesium Fluoride
- Magnesium Hydroxide
- Magnesium Nitrate
- Magnesium Oxide
- Magnesium Sulfate
- Maleic Acid
- Malic Acid
- Manganese Sulfate
- Mercuric Chloride
- Mercuric Cyanide
- Mercuric Sulfate
- Mercurous Nitrate
- Mercury
- Methanesulfonic Acid
- Methanol, up to 10%
- Methanol, >10%
- Methanol, pure
- Methyl Acetate, up to 5%
- Methyl Acetate, >5%
- Methyl Acetate, pure
- Methyl Cellosolve
- Methyl Ethyl Ketone
- Methyl Formate
- Methyl Isobutyl Ketone
- Methyl Isopropyl Ketone
- Methyl Methacrylate
- Methylamine
- Mineral Oil
- Molasses
- Monoethanolamine
- Morpholine
- Muriatic Acid
- Nickel Acetate
- Nickel Chloride
- Nickel Nitrate
- Nickel Sulfate
- Nitric Acid
- Nitrous Acid
- Octane
- Octanol
- Oleum
- Oxalic Acid
- Ozonized Water
- Paraffn
- Peracetic Acid
- Perchloric Acid, 10%
- Phenol, up to 5%
- Phenol, >5%
- Phenol, pure
- Phosphoric Acid
- Phosphorus Pentoxide
- Phosphorus Trichloride
- Photographic Solutions
- Pine Oil
- Plating Solutions
- Polyethylene Glycol
- Polyvinyl Alcohol
- Potash
- Potassium Acetate
- Potassium Bicarbonate
- Potassium Bichromate
- Potassium Bisulfate
- Potassium Borate
- Potassium Bromate
- Potassium Bromide
- Potassium Carbonate
- Potassium Chlorate
- Potassium Chloride
- Potassium Chromate
- Potassium Cyanate
- Potassium Cyanide
- Potassium Dichromate
- Potassium Ferricyanide
- Potassium Ferrocyanide
- Potassium Fluoride
- Potassium Hydroxide
- Potassium Hypochlorite
- Potassium Iodide
- Potassium Nitrate
- Potassium Perborate
- Potassium Perchlorate
- Potassium Permanganate
- Potassium Persulfate
- Potassium Phosphate
- Potassium Sulfate
- Potassium Sulfde
- Potassium Sulfte
- Potassium Tripolyphosphate
- Propanol, up to 1%
- Propanol, >1%
- Propanol, pure
- Propargyl Alcohol
- Propionic Acid, up to 5%
- Propionic Acid, >5%
- Propionic Acid, pure
- Propyl Acetate
- Propylene Glycol, up to 25%
- Propylene Glycol, >25%
- Propylene Oxide
- Pyridine
- Pyrogallol
- Pyrrole
- Salicylaldehyde
- Sea Water
- Silicic Acid
- Silicone Oil
- Silver Chloride
- Silver Cyanide
- Silver Nitrate
- Silver Sulfate
- Soaps
- Sodium Acetate
- Sodium Aluminate
- Sodium Arsenate
- Sodium Benzoate
- Sodium Bicarbonate
- Sodium Bichromate
- Sodium Bisulfate
- Sodium Bisulfte
- Sodium Borate
- Sodium Bromide
- Sodium Carbonate
- Sodium Chlorate
- Sodium Chloride
- Sodium Chlorite
- Sodium Chromate
- Sodium Cyanide
- Sodium Dichromate
- Sodium Ferricyanide
- Sodium Ferrocyanide
- Sodium Fluoride
- Sodium Formate
- Sodium Hydroxide
- Sodium Hypobromite
- Sodium Hypochlorite
- Sodium Iodide
- Sodium Metaphosphate
- Sodium Nitrate
- Sodium Nitrite
- Sodium Palmitate
- Sodium Perborate
- Sodium Perchlorate
- Sodium Peroxide
- Sodium Phosphate
- Sodium Silicate
- Sodium Sulfate
- Sodium Sulfde
- Sodium Sulfte
- Sodium Thiosulfate
- Sodium Tripolyphosphate
- Stannic Chloride
- Stannous Chloride
- Stannous Sulfate
- Starch
- Stearic Acid
- Strontium Chloride
- Succinic Acid
- Sugar
- Sulfamic Acid
- Sulfuric Acid
- Sulfurous Acid
- Tannic Acid
- Tartaric Acid
- Tetrahydrofuran
- Tetrahydronaphthalene
- Tetrasodium pyrophosphate
- Thionyl Chloride
- Tomato Juice
- Tributyl Citrate
- Tributyl Phosphate
- Trichloroacetic Acid
- Triethanolamine
- Triethylamine
- Trimethyl Propane
- Trisodium Phosphate
- Urea
- Urine
- Vinegar
- Vinyl Acetate
- Water
- Whiskey
- White Liquor
- Wine
- Zinc Acetate
- Zinc Carbonate
- Zinc Chloride
- Zinc Nitrate
- Zinc Sulfate
Chemicals Not Recommended
- Allyl Chloride
- Asphalt
- Benzyl Chloride
- Bromobenzene
- Bromotoluene
- Carbon Tetrachloride
- Chlorobenzene
- Chloroform
- Creosote
- Cresol
- Dibutoxyethyl Phthalate
- Dibutyl Phthalate
- Dibutyl Sebacate
- Dichloroethylene
- Dimethyl Phthalate
- Dioctyl Phthalate
- Ethyl Chloride
- Ethyl Chloroacetate
- Ethylene Bromide
- Ethylene Chloride
- Ethylene Chlorohydrin
- Halocarbon Oils
- Isopropyl Chloride
- Methyl Chloride
- Methyl Chloroform
- Methylene Bromide
- Methylene Chloride
- Methylene Chlorobromide
- Methylene Iodide
- Phosphate Esters
- Propyl Bromide
- Propylene Dichloride
- Trichloroethylene
Chemicals used with Caution
Be suspicious with certain stress levels.
- Acetophenone
- Amines
- Amyl Acetate
- Amyl Alcohol, >1%
- Amyl Alcohol, pure
- Amyl Chloride
- Aniline
- Aniline Hydrochloride
- Anthraquinone
- Benzaldehyde
- Benzene
- Butyl Acetate
- Butyl Phenol
- Carbon Disulfde
- Castor Oil
- Coconut Oil
- Corn Oil
- Cottonseed Oil
- Cumene
- Diesel Fuel
- Ethyl Benzene
- Fatty Acids
- Fish Oil
- Lard Oil
- Lauryl Chloride
- Linoleic Acid
- Linseed Oil
- Motor Oil
- Naphtha
- Naphthalene
- Nitrobenzene
- Nitroethane
- Nitroglycerine
- Nitromethane
- Oil, Crude
- Olive Oil
- Palm Oil
- Peanut Oil
- Phenylhydrazine
- Phthalic Acid
- Picric Acid
- Soybean Oil
- Styrene
- Tall Oil
- Toluene
- Tung Oil
- Turpentine
- Vegetable Oils
- Xylene
Search the Engineering ToolBox
Custom Search
Related Topics
-
Corrosion