Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

This is an AMP page - Open full page! for all features.

Compressed Air - Size of Pipe vs. Capacity

Sponsored Links

Recommended air pipe line sizes with schedule 40 steel pipes and air pressure 100 psi (6.9 bar, 689500 Pa):

Compressed Air - Recommended Size of Pipe vs. Capacity

Free Air Flow
(cfm)

Recommended Pipe Size (inches)
Length of Pipe (feet)
255075100150200250
5 1/2 1/2 1/2 1/2 1/2 1/2 1/2
10 1/2 1/2 1/2 1/2 1/2 1/2 1/2
15 1/2 1/2 1/2 1/2 3/4 3/4 3/4
20 1/2 1/2 3/4 3/4 3/4 3/4 3/4
25 1/2 3/4 3/4 3/4 3/4 1 1
30 1/2 3/4 3/4 3/4 1 1 1
35 3/4 3/4 3/4 3/4 1 1 1
40 3/4 3/4 3/4 1 1 1 1
45 3/4 3/4 1 1 1 1 1 1/4
50 3/4 1 1 1 1 1 1/4 1 1/4
55 3/4 1 1 1 1 1/4 1 1/4 1 1/4
60 3/4 1 1 1 1 1/4 1 1/4 1 1/4
65 3/4 1 1 1 1 1/4 1 1/4 1 1/4
70 3/4 1 1 1 1/4 1 1/4 1 1/4 1 1/4
75 1 1 1 1 1/4 1 1/4 1 1/4 1 1/4
80 1 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
85 1 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
90 1 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2
95 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2
100 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2
Sponsored Links

Related Topics

Gases and Compressed Air

Properties of air, LNG, LPG and other common gases. Pipeline capacities and sizing of relief valves.

Related Documents

Compressed Air - Friction Loss in Hoses

Friction loss in air hoses vs. operating pressure.

Compressed Air - Pipe Line Pressure Loss - Online Calculator with Metric and Imperial Units

Calculate pressure drop in compressed air pipe lines - metric and imperial units.

Compressed Air - Pressure Drop Diagrams, Metric Units

Pressure loss in compressed air pipe lines.

Compressed Air Pipe Line Capacity

Capacities of compressed air pipelines - pressure ranging 5 - 250 psi (0.5 - 17 bar).

Compressed Air Pipe Lines - Pressure Loss vs. Capacity and Operating Pressure

Pressure drop in compressed air pipe lines.

Compressed Air Pipes - Fittings and Pressure Loss

Fittings in compressed air pipe lines and equivalent length pressure drop.

Compressed Air Piping - Pressure Loss Diagrams, Imperial Units

Pressure drop in compressed air pipelines with applied pressure 50, 100 and 150 psi.

Pneumatic Piping - Pressure Loss vs. Air Flow

Pressure loss in pneumatic tubes - sizes ranging 5 - 36 mm.

Sponsored Links

Search Engineering ToolBox

  • the most efficient way to navigate the Engineering ToolBox!

SketchUp Extension - Online 3D modeling!

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!

Privacy

We don't collect information from our users. Only emails and answers are saved in our archive. Cookies are only used in the browser to improve user experience.

Some of our calculators and applications let you save application data to your local computer. These applications will - due to browser restrictions - send data between your browser and our server. We don't save this data.

Google use cookies for serving our ads and handling visitor statistics. Please read Google Privacy & Terms for more information about how you can control adserving and the information collected.

AddThis use cookies for handling links to social media. Please read AddThis Privacy for more information.