Fruits and Vegetables - Optimal Storage Conditions
Optimal temperature and humidity conditions for common fruits and vegetables.
Proper storage conditions - temperature and humidity - are required to maximize storage life and maintain quality of harvested fruits and vegetables.
Fresh fruit need low temperature and high relative humidity to reduce the respiration and slow down the metabolic processes. The table below indicates optimal temperatures and moisture conditions for some common fruits and vegetables.
For full table with Chill Temperature, Freezing Point and Optimal Humidity - rotate the screen!
Product | Optimal Storage Temperature (oF) | Chill Point (oF) | Freezing Point (oF) | Optimal Humidity | Top Ice Accepted 1) | Water Sprinkle Accepted 2) | Ethylene Production | Sensitive to Ethylene 3) | Approximate Storage Life | Comments |
---|---|---|---|---|---|---|---|---|---|---|
% | ||||||||||
Apples | 30 - 40 | 29.3 | 90-95 | No | No | High | Yes | 1-12 months | Chill sensitive stored at 35-40 F (2-4 C) | |
Apricots | 31 - 32 | 30.1 | 90-95 | No | No | High | Yes | 1-3 weeks | ||
Artichokes | 32 - 35 | 90-95 | Yes | Yes | No | No | ||||
Artichokes, Jerusalem | 31 - 32 | 28.0 | 90-95 | No | No | No | No | 4-5 months | ||
Asparagus | 32 - 35 | 30.9 | 95-100 | No | Yes | No | Yes | 2-3 weeks | ||
Avocados, ripe | 38 - 45 | 36 | 85-95 | No | No | High | Yes | |||
Avocados, unripe | 45 - 50 | 45 | 85-95 | No | No | Low | Yes, Very | Keep away from ethylene producing fruits | ||
Bananas, green | 62 - 70 | 56 | 85-95 | No | No | Low | Yes | |||
Bananas, ripe | 56 - 60 | 54 | 85-95 | No | No | Medium | No | |||
Basil | 52 - 59 | 50 | 90-95 | No | Yes | No | Yes | |||
Beans, dry | 40 - 50 | 40-50 | 6-10 months | |||||||
Beans, green or snap | 40 - 45 | 30.7 | 95 | 7-10 days | ||||||
Beans, sprouts | 32 | 95-100 | 7-9 days | |||||||
Beans. Lima | 37 - 41 | 31.0 | 95 | 5-7 days | ||||||
Beets | 32 - 35 | 90-95 | Yes | Yes | No | Yes | ||||
Beets, bunched | 32 | 31.3 | 98-100 | 10-14 days | ||||||
Beets, topped | 32 | 30.3 | 98-100 | 4-6 months | ||||||
Blackberries | 32 - 33 | 30.5 | 90-95 | No | No | Very Low | No | 2-3 days | ||
Blueberries | 32 - 35 | 90-95 | No | No | Very Low | No | ||||
Bok Choy | 32 - 35 | 90-95 | No | Yes | No | Yes | ||||
Broccoli | 32 | 30.9 | 95-100 | Yes | Yes | No | Yes | 10-14 days | ||
Brussels Sprouts | 32 | 30.5 | 90-95 | Yes | Yes | No | Yes | 3-5 weeks | ||
Bunched Greens | 32 | 90-95 | Yes | Yes | No | Yes | Beets, Chard, Green Onions, Mustard, Parsley, Radish, Spinach, Turnip | |||
Cabbage, Chinese | 32 | 95-100 | No | No | No | Yes | 2-3 months | |||
Cabbage, early | 32 | 30.4 | 98-100 | Yes | Yes | No | Yes | 3-6 weeks | ||
Cabbage, late | 32 | 30.4 | 98-100 | 5-6 months | ||||||
Cantaloupe | 36 - 38 | 34 | 90-95 | No | No | Medium | Yes | |||
Carrots, bunched | 32 | 95-100 | Yes | Yes | No | Yes | 2 weeks | Ethylene may cause a bitter flavor | ||
Carrots, immature | 32 | 29.5 | 98-100 | 4-6 weeks | ||||||
Carrots, mature | 32 | 29.5 | 98-100 | 7-9 months | ||||||
Cauliflower | 32 | 30.6 | 95-98 | 3-4 weeks | ||||||
Cauliflower | 32 - 35 | 90-95 | No | No | No | Yes | ||||
Celery | 32 | 31.1 | 98-100 | Yes | Yes | No | Yes | 2-3 months | ||
Celeriac | 32 | 30.3 | 97-99 | 6-8 months | ||||||
Chard | 32 | 95-100 | 10-14 days | |||||||
Cherries | 32 - 35 | 90-95 | No | No | Very Low | No | ||||
Cherries, sour | 32 | 29.0 | 90-95 | 3-7 days | ||||||
Cherries, sweet | 30 - 31 | 28.8 | 90-95 | 2-3 weeks | ||||||
Chicory | 32 - 35 | 90-95 | Yes | Yes | No | No | ||||
Chicory, witloof | 32 | 95-100 | 2-4 weeks | |||||||
Chinese Pea Pods | 32 - 35 | 90-95 | No | No | No | No | ||||
Coconuts | 55 - 60 | 80-85 | No | No | No | No | Extended storage 32-35 F (0-2 C) | |||
Collards | 32 | 30.6 | 95-100 | 10-14 days | ||||||
Corn, sweet | 32 | 30.9 | 95-98 | Yes | Yes | No | No | 5-8 days | ||
Cranberries | 38 - 42 | 36 | 90-95 | Yes | No | No | No | |||
Cucumbers | 50 - 55 | 40 | 31.1 | 95 | No | No | Very Low | Yes | 10-14 days | |
Currants | 31 - 32 | 30.2 | 90-95 | 1-4 weeks | ||||||
Eggplant | 46 - 54 | 45 | 30.6 | 90-95 | No | No | No | Yes | 1 week | |
Elderberries | 31 - 32 | 90-95 | 1-2 weeks | |||||||
Endive | 32 | 31.9 | 95-100 | Yes | Yes | No | No | 2-3 weeks | ||
Escarole | 32 - 35 | 90-95 | Yes | Yes | No | No | ||||
Escarole | 32 | 31.9 | 95-100 | 2-3 weeks | ||||||
Figs | 32 - 35 | 90-95 | No | No | Low | No | ||||
Garlic | 32 | 30.5 | 65-70 | No | No | No | No | 6-7 months | May be stored at 55-70 F (13-21 C) for shorter periods | |
Ginger Root | 60 - 65 | 55 | 65-70 | No | No | No | No | |||
Gooseberries | 31 - 32 | 30.0 | 90-95 | 3-4 weeks | ||||||
Grapefruit | 55 - 60 | 50 | 90-95 | No | No | Very Low | No | |||
Grapes | 31 - 32 | 29.7 | 85 | No | No | Very Low | Yes | 2-8 weeks | ||
Green Beans | 40 - 45 | 38 | 90-95 | No | No | No | Yes | |||
Green Peas | 32 - 35 | 90-95 | No | No | No | Yes | ||||
Greens, leafy | 32 | 95-100 | 10-14 days | |||||||
Guavas | 45 - 50 | 40 | 90-95 | No | No | Medium | Yes | |||
Herbs | 32 - 35 | 90-95 | No | Yes | No | Yes | ||||
Horseradish | 30 - 32 | 28.7 | 98-100 | 10-12 months | ||||||
Jicama | 55 - 65 | 65-70 | 1-2 months | |||||||
Kale | 32 | 31.1 | 95-100 | 2-3 weeks | ||||||
Kiwi, ripe | 32 - 35 | 90-95 | No | No | High | Yes | ||||
Kiwi, unripe | 32 - 35 | 90-95 | Ne | No | Low | Yes, Very | ||||
Kohlrabi | 32 | 30.2 | 98-100 | Yes | Yes | No | No | 2-3 months | ||
Leeks | 32 | 30.7 | 95-100 | Yes | Yes | No | Yes | 2-3 months | ||
Lemons | 52 - 55 | 50 | 90-95 | No | No | Very Low | No | |||
Lettuce | 32 | 31.7 | 98-100 | No | Yes | No | Yes | 2-3 weeks | ||
Limes | 48 - 55 | 45 | 90-95 | No | No | Very Low | No | |||
Lychees | 40 - 45 | 36 | 90-95 | No | No | Very Low | No | |||
Mangos | 50 - 55 | 50 | 85-95 | No | No | Medium | Yes | |||
Melons, Casaba/Persian | 50 - 55 | 45 | 85-95 | No | No | Very Low | Yes | Riper melons may be stored at 45-50 F (7-10 C) | ||
Melons, Crenshaw | 50 - 55 | 45 | 85-95 | No | No | Low | Yes | Riper melons may be stored at 45-50 F (7-10 C) | ||
Melons, Honey Dew | 50 - 55 | 41 | 85-95 | No | No | Medium | Yes | Riper melons may be stored at 45-50 F (7-10 C) | ||
Mushrooms | 32 | 30.4 | 95 | No | Yes | No | Yes | 3-4 days | ||
Napa | 32 - 35 | 90-95 | No | No | No | Yes | ||||
Nectarines | 31 - 32 | 30.4 | 90-95 | No | No | High | No | 2-4 weeks | ||
Okra | 45 - 50 | 45 | 28.7 | 90-95 | No | No | Very Low | Yes | 7-10 days | |
Onions | 32 - 35 | 65-75 | No | No | No | No | May be stored at 55-70 F (13-21 C) for shorter period | |||
Oranges | 40 - 45 | 38 | 90-95 | No | No | Very Low | No | |||
Papayas | 50 - 55 | 45 | 85-95 | No | No | Medium | Yes | |||
Parsley | 32 | 30.0 | 95-100 | 2-3 months | ||||||
Parsnips | 32 | 30.4 | 98-100 | Yes | Yes | No | Yes | 4-6 months | ||
Peaches | 31 - 32 | 30.3 | 90-95 | No | No | High | Yes | 2-4 weeks | ||
Pears | 29 - 31 | 29.2 | 90-95 | No | No | High | Yes | 2-7 months | ||
Peas, green | 32 | 30.9 | 95-98 | 1-2 weeks | ||||||
Peas, southern | 40 - 41 | 95 | 6-8 days | |||||||
Peppers, hot chili | 32 - 50 | 60-70 | No | No | No | Yes | 6 months | |||
Peppers, sweet | 45 - 55 | 42 | 30.7 | 90-95 | No | No | No | No | 2-3 weeks | |
Persimmons | 32 - 35 | 90-95 | No | No | No | Yes, Very | ||||
Pineapples | 50 - 55 | 45 | 85-95 | No | No | Very Low | No | Odor may influence avacados | ||
Plums | 31 - 32 | 30.5 | 90-95 | No | No | High | Yes | 2-5 weeks | ||
Pomegranates | 41 - 50 | 41 | 90-95 | No | No | No | No | |||
Potatoes | 45 - 50 | 38 | 90-95 | No | No | No | Yes | |||
Precut Fruit | 32 - 36 | 90-95 | No | No | Low | No | ||||
Precut Vegetables | 32 - 36 | 90-95 | No | No | No | Yes | ||||
Prunes | 31 - 32 | 30.5 | 90-95 | No | No | High | Yes | 2-5 weeks | ||
Pumpkins | 50 - 55 | 50 | 30.5 | 65-70 | No | No | No | Yes | 2-3 months | |
Quinces | 31 - 32 | 28.4 | 90 | 2-3 months | ||||||
Quinces | 32 - 35 | 90-95 | No | No | High | Yes | ||||
Radishes, spring | 32 | 30.7 | 95-100 | Yes | Yes | No | Yes | 3-4 weeks | ||
Radishes, winter | 32 | 95-100 | 2-4 months | |||||||
Raspberries | 31 - 32 | 30.0 | 90-95 | No | No | Very Low | No | 2-3 days | ||
Rhubarb | 32 | 30.3 | 95-100 | No | Yes | No | No | 2-4 weeks | ||
Rutabagas | 32 | 30.0 | 98-100 | Yes | Yes | No | Yes | 4-6 months | ||
Salad Mixes | 32 - 35 | 90-95 | No | Yes | No | Yes | ||||
Salsify | 32 | 30.0 | 95-98 | 2-4 months | ||||||
Spinach | 32 | 31.5 | 95-100 | 10-14 days | ||||||
Sprouts | 32 - 35 | 90-95 | No | No | No | Yes | ||||
Squashes, summer | 41 - 50 | 40 | 31.1 | 95 | No | No | No | Yes | 1-2 weeks | |
Squashes, winter | 50 | 30.5 | 50-70 | No | No | No | Yes | 1-6 months | ||
Strawberries | 32 | 30.6 | 90-95 | No | No | Very Low | No | 3-7 days | ||
Sweet Potatoes | 55 - 60 | 54 | 29.7 | 85-90 | No | No | No | Yes | 4-7 months | |
Tangerines | 32 - 35 | 90-95 | No | No | Very Low | No | ||||
Tangerines | 40 - 45 | 38 | 90-95 | No | No | Very Low | No | |||
Tomatoes, mature green | 55 - 70 | 31.0 | 90-95 | No | No | Low | Yes | 1-3 weeks | Riping can be delayed by storing at 55-60 F (13-16 C) | |
Tomatoes, ripe | 55 - 70 | 31.1 | 90-95 | No | No | Medium | No | 4-7 days | ||
Turnip greens | 32 | 31.7 | 95-100 | 10-14 days | ||||||
Turnips | 32 | 30.1 | 95 | Yes | Yes | No | Yes | 4-5 months | ||
Watercress | 32 | 31.4 | 95-100 | 2-3 weeks | ||||||
Watermelon | 55 - 70 | 50 | 85-95 | No | No | No | Yes, Very | Keep away from ethylene producing fruits |
1) Top icing the products may be very effective keeping the temperature low and the product surface close to 100% humidity.
2) Spraying with water may be effective by keeping the temperature low (evaporative cooling) and the surface 100% humid.
3) Products sensitive to ethylene should not be stored together with products producing ethylene. Exposure to ethylene may soften the flesh, adding bitter taste to the product or/and accelerate ripening.
Related Topics
-
Air Conditioning Systems
Design of Air Conditioning systems - heating, cooling and dehumidification of indoor air for thermal comfort. -
Miscellaneous
Engineering related topics like Beaufort Wind Scale, CE-marking, drawing standards and more.
Related Documents
-
Food - Energy Content
Energy in carbohydrates, fats and proteins. -
Food and Foodstuff - pH Values
pH in common food products - like apples, butter, wines and more. -
Food and Foodstuff - Specific Heat
Specific heat of common food and foodstuff like apples, bass, beef, pork and many more. -
Food Products - Osmotic Pressures
Osmotic pressure in food products. -
Food-borne Infections and Diseases
Common bacteria and viruses found in food. -
Foods - Thermal Conductivities
Thermal conductivity of selected foodstuff like apples, beef, sugar and more. -
Foodstuff - Thermal Diffusivity
Thermal diffusivity of some selected food products. -
Frozen Food - Storage Life
Practical storage life for common frozen food products. -
Indoor Conditions - Summer or Winter
Recommended indoor design conditions summer or winter. -
Industrial Product and Production Processes - Climate Conditions
Recommended indoor temperature and humidity for common industrial products and production processes. -
Moisture Content Calculation
Calculate the moisture content in products like wood on wet and dry basis. -
Pasteurization - Temperatures and Time
Pasteurization methods, time and temperatures. -
Water Content in Food and other Products
Water content before and after drying - in food and other products cork, grain, soap, peat, wood and more.