Water - Thermal Conductivity vs. Temperature
Figures and tables showing thermal conductivity of water (liquid and gas phase) with varying temperature and pressure, SI and Imperial units.
Thermal conductivity is a material property that describes ability to conduct heat. Thermal conductivity can be defined as
"the quantity of heat transmitted through a unit thickness of a material - in a direction normal to a surface of unit area - due to a unit temperature gradient under steady state conditions"
Thermal conductivity unit converter
The thermal conductivity of water depends on temperature and pressure as shown in the figures and tables below:
See also other properties of Water at varying temperature and pressure : Boiling points at high pressure , Boiling points at vacuum pressure , Density and specific weight , Dynamic and kinematic viscosity , Enthalpy and entropy , Heat of vaporization , Ionization Constant, pK w , of normal and heavy water , Melting points at high pressure , Prandtl number , Properties at Gas-Liquid Equilibrium Conditions , Saturation pressure , Specific gravity , Specific heat (heat capacity) , Specific volume , Thermal diffusivity and Vapour pressure at gas-liquid equilibrium , and Thermophysical properties at standard conditions ,
as well as thermal conductivity o f air , ammonia , butane , carbon dioxide , ethylene , hydrogen , methane , nitrogen and propane . For thermal conductivity of construction materials, see related documents at the bottom of the page.
Thermal conductivity of water at given temperatures (°C) and 1 bara:
State of water |
Temperature | Thermal conductivity | ||
[°C] | [mW/m K] | [kcal(IT)/(h m K)] | [Btu(IT)/(h ft °F)] | |
Liquid | 0.01 | 555.75 | 0.4779 | 0.3211 |
10 | 578.64 | 0.4975 | 0.3343 | |
20 | 598.03 | 0.5142 | 0.3455 | |
30 | 614.50 | 0.5284 | 0.3551 | |
40 | 628.56 | 0.5405 | 0.3632 | |
50 | 640.60 | 0.5508 | 0.3701 | |
60 | 650.91 | 0.5597 | 0.3761 | |
70 | 659.69 | 0.5672 | 0.3812 | |
80 | 667.02 | 0.5735 | 0.3854 | |
90 | 672.88 | 0.5786 | 0.3888 | |
99.6 | 677.03 | 0.5821 | 0.3912 | |
Gas | 100 | 24.57 | 0.0211 | 0.0142 |
125 | 26.66 | 0.0229 | 0.0154 | |
150 | 28.83 | 0.0248 | 0.0167 | |
175 | 31.09 | 0.0267 | 0.0180 | |
200 | 33.43 | 0.0287 | 0.0193 | |
225 | 35.85 | 0.0308 | 0.0207 | |
250 | 38.34 | 0.0330 | 0.0222 | |
275 | 40.91 | 0.0352 | 0.0236 | |
300 | 43.53 | 0.0374 | 0.0252 | |
350 | 48.98 | 0.0421 | 0.0283 | |
400 | 54.65 | 0.0470 | 0.0316 | |
450 | 60.52 | 0.0520 | 0.0350 | |
500 | 66.58 | 0.0573 | 0.0385 | |
550 | 72.81 | 0.0626 | 0.0421 | |
600 | 79.17 | 0.0681 | 0.0457 | |
700 | 92.28 | 0.0794 | 0.0533 | |
800 | 105.81 | 0.0910 | 0.0611 | |
900 | 119.67 | 0.1029 | 0.0691 |
Thermal conductivity of water at given temperatures (°F) and 14.5 psia:
State of water | Temperature | Thermal conductivity | |||
[°F] | [Btu(IT)/(h ft °F)] | [Btu(IT) in/(h ft2°F)] | [mW/m K] | [x 10-3 cal(IT)/(s cm2K)] |
|
Liquid | 32 | 0.3211 | 3.853 | 555.73 | 1.327 |
40 | 0.3273 | 3.927 | 566.39 | 1.353 | |
60 | 0.3408 | 4.089 | 589.80 | 1.409 | |
80 | 0.3520 | 4.225 | 609.30 | 1.455 | |
100 | 0.3615 | 4.338 | 625.62 | 1.494 | |
120 | 0.3694 | 4.433 | 639.35 | 1.527 | |
140 | 0.3761 | 4.513 | 650.91 | 1.555 | |
160 | 0.3817 | 4.580 | 660.57 | 1.578 | |
180 | 0.3862 | 4.635 | 668.45 | 1.597 | |
200 | 0.3897 | 4.677 | 674.49 | 1.611 | |
211.3 | 0.3912 | 4.694 | 677.03 | 1.617 | |
Gas | 212 | 0.0142 | 0.170 | 24.57 | 0.059 |
250 | 0.0152 | 0.183 | 26.33 | 0.063 | |
300 | 0.0166 | 0.199 | 28.73 | 0.069 | |
350 | 0.0181 | 0.217 | 31.25 | 0.075 | |
400 | 0.0196 | 0.235 | 33.86 | 0.081 | |
450 | 0.0211 | 0.254 | 36.56 | 0.087 | |
550 | 0.0244 | 0.293 | 42.24 | 0.101 | |
600 | 0.0261 | 0.313 | 45.20 | 0.108 | |
650 | 0.0279 | 0.334 | 48.24 | 0.115 | |
700 | 0.0297 | 0.356 | 51.35 | 0.123 | |
750 | 0.0315 | 0.378 | 54.52 | 0.130 | |
800 | 0.0334 | 0.400 | 57.76 | 0.138 | |
900 | 0.0372 | 0.447 | 64.41 | 0.154 | |
1000 | 0.0412 | 0.494 | 71.27 | 0.170 | |
1100 | 0.0453 | 0.543 | 78.32 | 0.187 | |
1200 | 0.0494 | 0.593 | 85.53 | 0.204 | |
1400 | 0.0580 | 0.696 | 100.35 | 0.240 | |
1600 | 0.0668 | 0.802 | 115.63 | 0.276 |
Related Topics
-
Material Properties
Properties of gases, fluids and solids. Densities, specific heats, viscosities and more. -
Steam and Condensate
Design of steam & condensate systems with properties, capacities, sizing of pipe lines, system configuration and more. -
Thermodynamics
Calculate heat, work, temperature and energy. The thermodynamics of steam and condensate systems. Water and Ice properties. -
Thermodynamics
Work, heat and energy systems. -
Water Systems
Design of hot and cold water service and utility systems with properties, capacities, sizing of pipe lines and more.
Related Documents
-
Air - Thermal Conductivity vs. Temperature and Pressure
Online calculator with figures and tables showing air thermal conductivity vs. temperature and pressure. SI and imperial units. -
Ammonia - Thermal Conductivity vs. Temperature and Pressure
Online calculator, figures and tables showing thermal conductivity of liquid and gaseous ammonia at temperatures ranging -70 to 425 °C (-100 to 800 °F) at atmospheric and higher pressure - Imperial and SI Units. -
Benzene Liquid - Thermal Properties
Properties like density, specific heat, thermal conductivity, dynamic viscosity and Prandtl number. -
Calcium Silicate Insulation
Thermal conductivity of calcium silicate insulation - temperature and k-values. -
Carbon dioxide - Thermal Conductivity vs. Temperature and Pressure
Online calculator, figures and table showing thermal conductivity of carbon dioxide, CO2, at temperatures ranging from -50 to 775 °C (-50 to 1400 °F) at atmospheric and higher pressure - Imperial and SI Units. -
Conductive Heat Transfer
Conductive heat transfer takes place in a solid if there is a temperature gradient. -
Fiberglass Insulation
Thermal conductivity of fiberglass insulation - temperature and k-values. -
Heat Exchanger Materials - Thermal Conductivities
Typical heat exchanger materials and their thermal conductivities. -
Heavy Water - Thermophysical Properties
Thermodynamic properties of heavy water (D2O) like density, melting temperature, boiling temperature, latent heat of fusion, latent heat of evaporation, critical temperature and more. -
Ice and Water - Melting Points vs. Pressure
Online calculator, figures and tables with melting points of ice to water at pressures ranging from 0 to 29000 psia (0 to 2000 bara). Temperature given as °C, °F, K and °R. -
Liquid Ammonia - Thermal Properties at Saturation Pressure
Density, specific heat, thermal conductivity, viscosity and Prandtls no. of liquid ammonia at saturation pressure. -
Liquids - Thermal Conductivities
Some fluids and their thermal conductivities. -
Metals, Metallic Elements and Alloys - Thermal Conductivities
Thermal conductivities of common metals, metallic elements aand alloys. -
Methane - Thermal Conductivity vs. Temperature and Pressure
Online calculator, figures and table showing thermal conductivity of methane, CH4, at temperatures ranging from -160 to 725 °C (-260 to 1300 °F) at atmospheric and higher pressure - Imperial and SI Units. -
Octane Liquid - Thermal Properties
Density, specific heat, thermal conductivity and more. -
Overall Heat Transfer Coefficients
Walls or heat exchangers - calculate overall heat transfer coefficients. -
Perlite Insulation
Thermal conductivity - k-values - vs. temperature. -
Pipes and Cylinders - Conductive Heat Losses
Conductive heat losses through cylinder or pipe walls. -
Plastics - Thermal Conductivity Coefficients
Thermal conductivity of plastics. -
Polyurethane Insulation
Thermal conductivity - k-values - vs. temperature. -
Propane - Thermal Conductivity vs. Temperature and Pressure
Online calculator, figures and tables showing thermal conductivity of liquid and gaseous propane at varying temperarure and pressure, SI and Imperial units. -
Solids, Liquids and Gases - Thermal Conductivities
Thermal conductivity coefficients for insulation materials, aluminum, asphalt, brass, copper, steel, gases and more. -
Thermal Conductivity - Online Converter
Convert between thermal conductivity units. -
Thermal Conductivity - Unit Converting Table
Convert between thermal conductivity units - table and diagram. -
Thermal Resistivity and Conductivity
The ability of a material to resist flow of heat. -
Toluene Liquid - Thermal Properties vs. Temperature
Density, specific heat, thermal conductivity and more. -
Transmission Heat Loss through Building Elements
Heat loss through common building elements due to transmission, R-values and U-values - imperial and SI units. -
Water - Boiling Points at Higher Pressures
Online calculator, figures and tables showing boiling points of water at pressures ranging from 14.7 to 3200 psia (1 to 220 bara). Temperature given as °C, °F, K and °R. -
Water - Boiling Points at Vacuum Pressure
Online calculator, figures and tables giving the boiling temperatures of water in varying vacuum, SI and Imperial units. -
Water - Density, Specific Weight and Thermal Expansion Coefficients
Definitions, online calculator and figures and tables with water properties like density, specific weight and thermal expansion coefficient of liquid water at temperatures ranging 0 to 360°C (32 to 680°F). -
Water - Dynamic (Absolute) and Kinematic Viscosity vs. Temperature and Pressure
Free online calculator - figures and tables with viscosity of water at temperatures ranging 0 to 360°C (32 to 675°F) - Imperial and SI Units. -
Water - Enthalpy and Entropy vs. Temperature
Figures and tables showing the enthalpy and entropy of liquid water as function of temperature - SI and Imperial Units. -
Water - Heat of Vaporization vs. Temperature
Online calculator, figures and tables showing heat of vaporization of water, at temperatures from 0 - 370 °C (32 - 700 °F) - SI and Imperial units. -
Water - Ionization Constant, pKw, of Normal and Heavy Water
Ionization constant (= dissociation constant = self-ionization constant = ion product = autoprotolysis constant ) of water and heavy water, given as function of temperature (°C and °F) in figures and tables. -
Water - Properties at Gas-Liquid Equilibrium Conditions
Figures and tables showing how the properties of water changes along the boiling/condensation curve (vapor pressure, density, viscosity, thermal conductivity, specific heat, Prandtl number, thermal diffusivity, entropy and enthalpy). -
Water - Saturation Pressure vs. Temperature
Online calculator, figures and tables with water saturation (vapor) pressure at temperatures ranging 0 to 370 °C (32 to 700°F) - in Imperial and SI Units. -
Water - Specific Gravity vs. Temperature
Figures and tables showing specific gravity of liquid water in the range of 32 to 700 °F or 0 to 370°C, using water density at four different temperatures as reference. -
Water - Specific Heat vs. Temperature
Online calculator, figures and tables showing specific heat of liquid water at constant volume or constant pressure at temperatures from 0 to 360 °C (32-700 °F) - SI and Imperial units. -
Water - Specific Volume vs. Temperature
Online calculator, figures and tables showing Specific Volume of water at temperatures ranging from 0-370 °C and 32 - 700 °F - Imperial and IS Units. -
Water - Thermal Diffusivity vs. Temperature and Pressure
Figures and tables with thermal diffusivity of liquids and gaseous water at varying temperarures and pressures - SI and Imperial units. -
Water - Thermophysical Properties
Thermal properties of water at different temperatures like density, freezing temperature, boiling temperature, latent heat of melting, latent heat of evaporation, critical temperature and more. -
Water vs. Steam - Critical and Triple Points
Critical point is where vapor and liquid are indistinguishable and triple point is where ice, water and vapor coexist in thermodynamic equilibrium.