Gas or Vapor Formula Specific Heat Capacity Ratio of Specific Heats Individual Gas constant
- R -
cp
(kJ/kg K)
cv
(kJ/kg K)
cp
(Btu/lbmoF)
cv
(Btu/lbmoF)
κ =
cp / cv
cp - cv
(kJ/kg K)
cp - cv
(ft lbf/lbmoR)
Acetone
1.47 1.32 0.35 0.32 1.11 0.15
Acetylene C2H2 1.69 1.37 0.35 0.27 1.232 0.319 59.34
Air 1.01 0.718 0.24 0.17 1.40 0.287 53.34
Alcohol C2H5OH 1.88 1.67 0.45 0.4 1.13 0.22
Alcohol CH3OH 1.93 1.53 0.46 0.37 1.26 0.39
Ammonia NH3 2.19 1.66 0.52 0.4 1.31 0.53 96.5
Argon Ar 0.520 0.312 0.12 0.07 1.667 0.208
Benzene C6H6 1.09 0.99 0.26 0.24 1.12 0.1
Blast furnace gas 1.03 0.73 0.25 0.17 1.41 0.3 55.05
Bromine
0.25 0.2 0.06 0.05 1.28 0.05
Butatiene           1.12    
Butane C4H10 1.67 1.53 0.395 0.356 1.094 0.143 26.5
Carbon dioxide CO2 0.844 0.655 0.21 0.16 1.289 0.189 38.86
Carbon monoxide CO 1.02 0.72 0.24 0.17 1.40 0.297 55.14
Carbon disulphide
0.67 0.55 0.16 0.13 1.21 0.12
Chlorine Cl2 0.48 0.36 0.12 0.09 1.34 0.12
Chloroform
0.63 0.55 0.15 0.13 1.15 0.08
Combustion products 1
0.24

Ethane C2H6 1.75 1.48 0.39 0.32 1.187 0.276 51.5
Ether
2.01 1.95 0.48 0.47 1.03 0.06
Ethylene C2H4 1.53 1.23 0.4 0.33 1.240 0.296 55.08
Freon 22           1.18    
Helium He 5.19 3.12 1.25 0.75 1.667 2.08 386.3
Hexane           1.06    
Hydrogen H2 14.32 10.16 3.42 2.43 1.405 4.12 765.9
Hydrogen Chloride HCl 0.8 0.57 0.191 0.135 1.41 0.23 42.4
Hydrogen Sulfide H2S 0.243 0.187 1.32 45.2
Hydroxyl OH 1.76 1.27     1.384 0.489  
Methane CH4 2.22 1.70 0.59 0.45 1.304 0.518 96.4
Methyl Chloride CH3Cl 0.240 0.200 1.20 30.6
Natural Gas 2.34 1.85 0.56 0.44 1.27 0.5 79.1
Neon   1.03 0.618     1.667 0.412  
Nitric Oxide NO 0.995 0.718 0.23 0.17 1.386 0.277
Nitrogen N2 1.04 0.743 0.25 0.18 1.400 0.297 54.99
Nitrogen tetroxide
4.69 4.6 1.12 1.1 1.02 0.09
Nitrous oxide N2O 0.88 0.69 0.21 0.17 1.27 0.18 35.1
Oxygen O2 0.919 0.659 0.22 0.16 1.395 0.260 48.24
Pentane           1.07    
Propane C3H8 1.67 1.48 0.39 0.34 1.127 0.189 35.0
Propene (propylene) C3H6 1.5 1.31 0.36 0.31 1.15 0.18 36.8
Water Vapor
Steam 1 psia. 120 – 600 oF

1.93 1.46 0.46 0.35 1.32 0.462
Steam 14.7 psia. 220 – 600 oF
1.97 1.5 0.47 0.36 1.31 0.46
Steam 150 psia. 360 – 600 oF
2.26 1.76 0.54 0.42 1.28 0.5
Sulfur dioxide (Sulphur dioxide) SO2 0.64 0.51 0.15 0.12 1.29 0.13 24.1

Sponsored Links

Related Topics

  • Material Properties Material properties - density, heat capacity, viscosity and more - for gases, fluids and solids

Related Documents

Sponsored Links



Engineering ToolBox - SketchUp Edition - Online 3D modeling!

Engineering ToolBox - SketchUp Edition - enabled for use with the amazing, fun and free Google SketchUp.


Search the ToolBox

Google
Web The Engineering ToolBox

© The Engineering ToolBox 2005

9 6 19

handheld Engineering ToolBox - optimized for mobile devices! 3D Engineering ToolBox - draw and model technical applications!


.
Resources, Tools and Basic Information  for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!