Pipe Flanges and Gasket Dimensions

Gasket dimensions for pipe flanges and flange fittings ASME B16.5 Pipe Flanges and Flange Fittings

Sponsored Links

Gasket dimensions for ASME B16.5 Pipe Flanges and Flange Fittings - can be found in the table below.

Nominal Pipe Size Gasket Inside Diameter (ID)
(inch)
Gasket Outside Diameter (OD)
(inches)
Class 300 Class 400 Class 600 Class 900
1/2 0.84 2.12 2.12 2.12 2.50
3/4 1.06 2.62 2.62 2.62 2.75
1 1.31 2.88 2.88 2.88 3.12
1 1/4 1.66 3.25 3.25 3.25 3.50
1 1/2 1.91 3.75 3.75 3.75 3.88
2 2.38 4.38 4.38 4.38 5.62
2 1/2 2.88 5.12 5.12 5.12 6.50
3 3.50 5.88 5.88 5.88 6.62
4 4.50 7.12 7.00 7.62 8.12
5 5.56 8.50 8.38 9.50 9.75
6 6.62 9.88 9.75 10.50 11.38
8 8.62 12.12 12.00 12.62 14.12
10 10.75 14.25 14.12 15.75 17.12
12 12.75 16.62 16.50 18.00 19.62

The ASME B16.5 - 1996 Pipe Flanges and Flange Fittings standard covers pressure-temperature ratings, materials, dimensions, tolerances, marking, testing, and methods of designating openings for pipe flanges and flanged fittings.

The standard includes flanges with rating class designations 150, 300, 400, 600, 900, 1500, and 2500 in sizes NPS 1/2 through NPS 24, with requirements given in both metric and U.S units. The Standard is limited to flanges and flanged fittings made from cast or forged materials, and blind flanges and certain reducing flanges made from cast, forged, or plate materials. Also included in this Standard are requirements and recommendations regarding flange bolting, flange gaskets, and flange joints.

Sponsored Links

Related Topics

  • Dimensions Sizes and dimensions of pipes and tubes, and their fittings - inside and outside diameter, weight and more

Related Documents

Sponsored Links



Engineering ToolBox - SketchUp Edition - Online 3D modeling!

Engineering ToolBox - SketchUp Edition - enabled for use with the amazing, fun and free Google SketchUp.


Search the ToolBox

Google
Web The Engineering ToolBox

© The Engineering ToolBox 2005

9 11 11

handheld Engineering ToolBox - optimized for mobile devices! 3D Engineering ToolBox - draw and model technical applications!


.
Resources, Tools and Basic Information  for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!