Hydraulic Force vs. Pressure and Cylinder Size
Calculate hydraulic cylinder force.

The force produced on the rod side (1) of a double acting hydraulic piston - can be expressed as
F1 = P1 (π (d22 - d12) / 4) (1)
where
F1 = rod force (lb, N)
d1 = rod diameter (in, mm)
d2= piston diameter (in, mm)
P1 = pressure in the cylinder on the rod side (psi, N/mm2)
- 1 bar = 105 N/m2= 0.1 Nm/mm2
The force produced on the opposite of rod side (2) - can be expressed as
F2= P2 (π d22 / 4) (2)
where
F2 = rod force (lb, N)
P2 = pressure in the cylinder (opposite rod) ( psi, N/mm2)
Hydraulic Force Calculator
Imperial Units
Pressure acting on rod side
Pressure acting on opposite of rod side
Metric Units
Pressure acting on rod side
Pressure acting on opposite of rod side
Related Mobile Apps from The Engineering ToolBox
- free apps for offline use on mobile devices.
Rod Force F2 diagram
- when pressure act on opposite side of rod.
Imperial Units

Metric Units
- 1 psi (lb/in2) = 144 psf (lbf/ft2) = 6,894.8 Pa (N/m2) = 6.895×10-3 N/mm2 = 6.895×10-2 bar
- 1 N/m2= 1 Pa = 1.4504×10-4 lb/in2= 1×10-5 bar = 4.03×10-3 in water = 0.336×10-3 ft water = 0.1024 mm water = 0.295×10-3 in mercury = 7.55×10-3 mm mercury = 0.1024 kg/m2= 0.993×10-5atm
- 1 lbf (Pound force) = 4.44822 N = 0.4536 kp
- 1 N (Newton) = 0.1020 kp = 7.233 pdl = 7.233/32.174 lbf = 0.2248 lbf = 1 (kg m)/s2= 105 dyne = 1/9.80665 kgf
- 1 in (inch) = 25.4 mm
- 1 m (meter) = 39.37 in = 100 cm = 1000 mm