The Construction Specifications Institute's (CSI) MasterFormat is the most widely used standard for organizing specifications for building projects in the U.S. and Canada.
MasterFormat organizes information by work results (materials and methods) with the primary purposes of organizing specifications and detailed cost information. MasterFormat is normally used from design development on in the design construction process.
Master-Format 2004 Edition:
PROCUREMENT AND CONTRACTING REQUIREMENTS GROUP
- Division 00 — Procurement and Contracting Requirements
SPECIFICATIONS GROUP
General Requirements Subgroup
- Division 01 — General Requirements
Facility Construction Subgroup
- Division 02 — Existing Conditions
- Division 03 — Concrete
- Division 04 — Masonry
- Division 05 — Metals
- Division 06 — Wood, Plastics, and Composites
- Division 07 — Thermal and Moisture Protection
- Division 08 — Openings
- Division 09 — Finishes
- Division 10 — Specialties
- Division 11 — Equipment
- Division 12 — Furnishings
- Division 13 — Special Construction
- Division 14 — Conveying Equipment
- Division 15 — RESERVED FOR FUTURE EXPANSION
- Division 16 — RESERVED FOR FUTURE EXPANSION
Facility Services Subgroup
- Division 20 — RESERVED FOR FUTURE EXPANSION
- Division 21 — Fire Suppression
- Division 22 — Plumbing
- Division 23 — Heating Ventilating and Air Conditioning
- Division 24 — RESERVED FOR FUTURE EXPANSION
- Division 25 — Integrated Automation
- Division 26 — Electrical
- Division 27 — Communications
- Division 28 — Electronic Safety and Security
- Division 29 — RESERVED FOR FUTURE EXPANSION
Site and Infrastructure Subgroup
- Division 30 — RESERVED FOR FUTURE EXPANSION
- Division 31 — Earthwork
- Division 32 — Exterior Improvements
- Division 33 — Utilities
- Division 34 — Transportation
- Division 35 — Waterways and Marine Construction
- Division 36 — RESERVED FOR FUTURE EXPANSION
- Division 37 — RESERVED FOR FUTURE EXPANSION
- Division 38 — RESERVED FOR FUTURE EXPANSION
- Division 39 — RESERVED FOR FUTURE EXPANSION
Process Equipment Subgroup
- Division 40 — Process Integration
- Division 41 — Material Processing and Handling Equipment
- Division 42 — Process Heating, Cooling, and Drying Equipment
- Division 43 — Process Gas and Liquid Handling, Purification and Storage Equipment
- Division 44 — Pollution Control Equipment
- Division 45 — Industry-Specific Manufacturing Equipment
- Division 46 — RESERVED FOR FUTURE EXPANSION
- Division 47 — RESERVED FOR FUTURE EXPANSION
- Division 48 — Electrical Power Generation
- Division 49 — RESERVED FOR FUTURE EXPANSION