Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

The Engineering ToolBox

Free tools and information for engineering and design of technical applications.

Steel Pipes - Thermal Expansion Loops

Calculating and sizing steel pipe thermal expansion loops.

Air - Thermophysical Properties

Thermal properties of air at different temperatures - density, viscosity, critical temperature and pressure, triple point, enthalpi and entropi, thermal conductivity and diffusivity and more.

Thermal Expansion - Linear Expansion Coefficients

Linear temperature expansion coefficients for common materials like aluminum, copper, glass, iron and many more.

Hot Air Balloons - Calculate Lifting Weights

Calculate hot air ballons lifting forces.

Poisson's Ratio

When a material is stretched in one direction it tends to get thinner in the other two directions.

Air - Psychrometric Chart for Standard Atmospheric Conditions - Imperial Units

Psychrometric chart for air at barometric pressure 29.921 inches of Mercury and temperature ranging 20oF to 120oF.

UTM to Latitude and Longitude Converter

Free online UTM to Latitude and Longitude coordinates converter.

Water - Thermophysical Properties

Thermal properties of water at different temperatures like density, freezing temperature, boiling temperature, latent heat of melting, latent heat of evaporation, critical temperature and more.

Radians vs. Degrees

Radian is the SI unit of angle. Convert between degrees and radians. Calculate angular velocity.

Miter Saw - Calculate Sawing Angle

Calculate miter saw protractor angles for skirting and decorative mouldings work.

Friction - Friction Coefficients and Calculator

Friction theory with calculator and friction coefficients for combinations of materials like ice, aluminum, steel, graphite and many more.

Young's Modulus, Tensile Strength and Yield Strength Values for some Materials

Young's Modulus (or Tensile Modulus alt. Modulus of Elasticity) and Ultimate Tensile Strength and Yield Strength for materials like steel, glass, wood and many more.

Solids, Liquids and Gases - Thermal Conductivities

Thermal conductivity coefficients for insulation materials, aluminum, asphalt, brass, copper, steel, gases and more.

Water - Density, Specific Weight and Thermal Expansion Coefficients

Definitions, online calculator and figures and tables with water properties like density, specific weight and thermal expansion coefficient of liquid water at temperatures ranging 0 to 360°C (32 to 680°F).

Numbers - Square, Cube, Square Root and Cubic Root Calculator

Calculate square, cube, square root and cubic root. Values tabulated for numbers ranging 1 to 100.

W-Beams - American Wide Flange Beams

Dimensions of American Wide Flange Beams ASTM A6 (or W-Beams) - Imperial units.

Viscosity - Absolute (Dynamic) vs. Kinematic

Vicosity is a fluid's resistance to flow and can be valued as dynamic (absolute) or kinematic.

AWG - American Wire Gauge Converting Chart

American Wire Gauge (AWG) vs. cross sectional area converter.

Density vs. Specific Weight and Specific Gravity

An introduction to density, specific weight and specific gravity.

Hot Water Heating Systems - Online Design Application

Free online design tool for designing hot water heating systems - metric units.

Water - Dynamic (Absolute) and Kinematic Viscosity vs. Temperature and Pressure

Free online calculator - figures and tables with viscosity of water at temperatures ranging 0 to 360°C (32 to 675°F) - Imperial and SI Units.

Flanges - ASME/ANSI B16.5 Flanges and Bolt Dimensions - Class 150 to 2500

Diameters and bolt circles for standard ASME B16.5 flanges - 1/4 to 24 inches - Class 150 to 2500.

Inches vs. mm - Conversion Chart

Convert fractional and/or decimal inches to metric mm - and vice versa.

Wrench Spanners - Inches vs. mm

Convert between US Inches and metric mm wrench and spanner sizes.

Area Moment of Inertia - Typical Cross Sections I

Typical cross sections and their Area Moment of Inertia.

Dry Air - Thermodynamic and Physical Properties

Thermodynamic properties of dry air - specific heat, ratio of specific heats, dynamic viscosity, thermal conductivity, Prandtl number, density and kinematic viscosity at temperatures ranging 175 - 1900 K.

Cars - New vs. Old Car Cost Calculator

Calculate and compare the costs between owning a new vs. an old car.

Acoustics

Room acoustics and acoustic properties. decibel A, B and C calculations. Noise Rating (NR) curves. Sound transmission through walls. Calculate sound pressure, sound intensity and sound attenuation.

Air Psychrometrics

Moist and humid air calculations. Psychrometric charts and Mollier diagrams. Air-condition systems temperatures, absolute and relative humidities and moisture content in air.

Basics

Basic engineering data. SI-system, unit converters, physical constants, drawing scales and more.

Combustion

Combustion processes and their efficiency. Boiler house and chimney topics. Properties of fuels like oil, gas, coal and wood and more. Safety valves and tanks.

Drawing Tools

2D and 3D engineering drawing tools.

Dynamics

Motion of bodies and the action of forces in producing or changing their motion - velocity and acceleration, forces and torque.

Economics

Engineering economics - cash flow diagrams, present value, discount rates, internal rates of return - IRR, income taxes, inflation.

Electrical

Electrical engineering with units, amps and electrical wiring. Wire gauges, electrical formulas, motors and more.

Environment

Climate, meteorology, solar, wind, emissions and environmental related engineering resources.

Fluid Mechanics

The study of fluids - liquids and gases. Involving velocity, pressure, density and temperature as functions of space and time.

Gases and Compressed Air

Properties of air, LNG, LPG and other common gases. Pipeline capacities and sizing of relief valves.

HVAC Systems

Design and sizing of Heating, Ventilation and Air Conditioning systems.

Hydraulics and Pneumatics

Hydraulic and pneumatic systems - fluids, forces, pumps and pistons.

Insulation

Calculate heat transfer and heat loss from buildings and technical applications. Heat transfer coefficients and insulation methods available for reduction of energy consumption.

Material Properties

Properties of gases, fluids and solids. Densities, specific heats, viscosities and more.

Mathematics

Mathematical rules and laws - numbers, areas, volumes, exponents, trigonometric functions and more.

Mechanics

The relationships between forces, acceleration, displacement, vectors, motion, momentum, energy of objects and more.

Miscellaneous

Engineering related topics like Beaufort Wind Scale, CE-marking, drawing standards and more.

Physiology

Human physiology vs. air quality, comfort temperatures, activity and metabolic rates. Health effects of gases adn polutions like carbon monoxide and more.

Piping Systems

Calculate dimensions of pipes and tubes. Pressure drop calculations and head loss charts. Use of different piping materials. Insulation of pipes and tubes and heat loss diagrams.

Process Control Systems

Instrumentation, design and documentation of process control systems.

Pumps

Design of pumping systems and pipelines. With centrifugal pumps, displacement pumps, cavitation, fluid viscosity, head and pressure, power consumption and more.

Sanitary Drainage Systems

The purpose of the sanitary drainage system is to remove effluent discharged from plumbing fixtures and other equipment.

Standard Organizations

National and International organizations producing codes and standards - ANSI, ISO, DIN, BSi and more.

Statics

Forces acting on bodies at rest under equilibrium conditions - loads, forces and torque, beams and columns.

Steam and Condensate

Design of steam & condensate systems with properties, capacities, sizing of pipe lines, system configuration and more.

Thermodynamics

Work, heat and energy systems.

Water Systems

Design of hot and cold water service and utility systems with properties, capacities, sizing of pipe lines and more.

Search

Search is the most efficient way to navigate the Engineering ToolBox.

Engineering ToolBox - SketchUp Extension - Online 3D modeling!

3D Engineering ToolBox Extension to SketchUp - add parametric components to your SketchUp model

Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with older versions of the amazing SketchUp Make and the newer "up to date" SketchUp Pro . Add the Engineering ToolBox extension to your SketchUp Make/Pro from the Extension Warehouse !

Translate this Page

Translate this page to Your Own Language .

About the Engineering ToolBox!

Privacy Policy

We don't collect information from our users. More about

We use a third-party to provide monetization technologies for our site. You can review their privacy and cookie policy here.

You can change your privacy settings by clicking the following button: .

Citation

This page can be cited as

  • Engineering ToolBox (2001) [online] Available at: https://www.engineeringtoolbox.com [Accessed Day Month Year].

Modify the access date according your visit.

3D Engineering ToolBox - draw and model technical applications! 2D Engineering ToolBox - create and share online diagram drawing templates! Engineering ToolBox Apps - mobile online and offline engineering applications!

Unit Converter

















































3.27.8

.